7. Technical data
Dimensions L x W x H 995 x 425 x 610 mm
Wood ø max 25 cm
Wood length max 37 cm
Weight 45 kg
Motor 230/50 V/Hz
Input P1 1500 W
Output P2 1100 W
Rating S1
Splitting Power max. 4 t
Cylinder rise 290 mm
Cylinder speed (fast fwd.) 3,86 cm/sec
Cylinder speed (return) 6,44 cm/sec
Hydraulic uid capacity 2,4 l
Operating pressure 165 bar
Motor speed 2850 1/min
Subject to technical changes!
Noise
m WARNING: Noise can have serious e󰀨ects on
your health. If the machine noise exceeds 85 dB (A),
please wear suitable hearing protection.
8. Unpacking
Open the packaging and remove the device care-
fully.
Remove the packaging material as well as the
packaging and transport bracing (if available).
Check that the delivery is complete.
Check the device and accessory parts for trans-
port damage.
In case of complaints the dealer must be informed
immediately. Subsequent complaints will not be ac-
cepted.
If possible, store the packaging until the warranty
period has expired.
Read the operating manual to make yourself famil-
iar with the device prior to using it.
Only use original parts for accessories as well as
for wearing and spare parts. Spare parts are avail-
able from your specialized dealer.
Specify our part numbers as well as the type and
year of construction of the device in your orders.
m ATTENTION
The device and packaging materials are not toys!
Children must not be allowed to play with plas-
tic bags, lm and small parts! There is a risk of
swallowing and su󰀨ocation!
6. Additional safety instructions
The log splitter may only be operated by one per-
son.
Never split logs containing nails, wire, or other for-
eign objects.
Already split wood and wood chips can be danger-
ous. You can stumble, slip or fall down. Keep the
working area tidy.
While the machine is switched on, never put your
hands on moving parts of the machine.
Only split logs with a maximum length of 37 cm.
m WARNING! This electric tool generates an elec-
tromagnetic eld during operation. This eld can im-
pair active or passive medical implants under cer-
tain conditions. In order to prevent the risk of serious
or deadly injuries, we recommend that persons with
medical implants consult with their physician and the
manufacturer of the medical implant prior to operat-
ing the electric tool.
Remaining hazards
The machine has been built using modern tech-
nology in accordance with recognized safety
rules. Some remaining hazards, however, may
still exist.
The splitting tool can cause injuries to ngers and
hands if the wood is incorrectly guided or support-
ed.
Thrown pieces can lead to injury if the work piece
is not correctly placed or held.
Injury through electric current if incorrect electric
connection leads are used.
Even when all safety measures are taken, some
remaining hazards which are not yet evident may
still be present.
Remaining hazards can be minimized by following
the safety instructions as well as the instructions in
the chapter Authorized use and in the entire oper-
ating manual.
Health hazard due to electrical power, with the use
of improper electrical connection cables.
Release the handle button and switch o󰀨 the ma-
chine prior to any operations.
Avoid accidental starts of the machine: Do not
press the start button while inserting the plug into
the socket.
Use the tools recommended in this manual to ob-
tain the best results from your machine.
Always keep hands away from the work area when
the machine is running.
21


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Scheppach HL460 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Scheppach HL460 in the language / languages: English, German, French, Italian as an attachment in your email.

The manual is 4.91 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info