782030
20
Zoom out
Zoom in
Previous page
1/100
Next page
www.scheppach.com / service@scheppach.com / +(49)-08223-4002-99 / +(49)-08223-4002-58
20 І GB
Using the attachments (Fig. 1):
R-Nozzle (10): For coarse cleaning work.
Kärcher-adapter (12): Use this adapter to attach
Kärcher brand accessories.
Terrace cleaner (13): For cleaning oor and wall sur-
faces.
Rotating brush (17): For surface cleaning
Cleaning brush (16): For surface cleaning.
H-nozzle (18): For eliminating stubborn dirt.
9. Electrical connections
The electrical motor installed is connected and
ready for operation. The connection complies
with the applicable VDE and DIN provisions.
The customers mains connection as well as
the extension cable used must also comply with
these regulations.
Damaged electrical connection cable
The insulation on electrical connection cables is of-
ten damaged.
This may have the following causes:
Passage points, where connection cables are
passed through windows or doors.
Kinks where the connection cable has been im-
properly fastened or routed.
Places where the connection cables have been cut
due to being driven over.
Insulation damage due to being ripped out of the
wall outlet.
Cracks due to the insulation ageing.
Such damaged electrical connection cables must not
be used and are life-threatening due to the insula-
tion damage.
Check the electrical connection cables for damage
regularly. Make sure that the connection cable does
not hang on the power network during the inspection.
Electrical connection cables must comply with the
applicable VDE and DIN provisions. Only use con-
nection cables with the marking „H05VV-F.
The printing of the type designation on the connec-
tion cable is mandatory.
AC motor
The mains voltage must be 230 V~
Extension cables up to 25 m long must have a
cross-section of 1.5 mm2.
Connections and repairs of electrical equipment may
only be carried out by an electrician.
Connect the accessory’s hose to the high-pressure
cleaner, and make sure that the suction strainer re-
mains under water.
Let the high-pressure cleaner run with the spray gun
removed until the water ows evenly out of the high-
pressure hose.
If no water comes out after 25 to 50 seconds, switch
off and check all connections.
Once the water is owing, turn off the high-pressure
cleaner and connect the spray gun and spray lance
to start work.
High-pressure hose connection (Fig. 3/4)
Connect the high-pressure hose (9) to the connec-
tion for the high-pressure hose (4). Remove the pro-
tective cover rst.
Insert the other end of the high-pressure hose (9)
into the pistol connection (8).
To remove the high-pressure hose (9), press the but-
ton (A) and pull it out.
Connecting the attachments (Fig. 5)
To mount attachments 7, 9, 11, 12, 16, 17 press them
into the pistol (8) and turn them until the lock.
To mount attachments 10, 13, 18 insert these into the
attachment (7) and turn them until they lock.
8. Operation
The equipment consists of an assembly with a pump,
which is encased in a shock absorbing housing. The
equipment comes with a lance and a non-slip gun (for
an optimal working position), whose shape and con-
guration comply with the applicable regulations.
Commissioning:
Once you have completely assembled the high-pres-
sure cleaner and all connections have been made,
proceed as follows:
Turn on the water supply. Unlock the pistol (8) via
the locking switch (C). Pull back the trigger lever (D)
so that the air in the device can discharge. (Fig. 5)
Switch on the device by setting the on/off switch (3)
to “ON. Next, press the trigger lever (D). (Fig. 1/5)
To switch off, release the trigger lever (D), and the
device switches to stand-by. The high-pressure
cleaner starts again when you press the trigger le-
ver (D). (Fig. 5)
To switch off the high-pressure cleaner completely,
set the on/off switch (3) to “OFF”. (Fig. 1)
Cleaner container (11)
Fill the cleaner container with the corresponding
cleaner. The beam width can be adjusted at the noz-
zle.
20


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Scheppach HCE1650 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Scheppach HCE1650 in the language / languages: English, German, French, Italian as an attachment in your email.

The manual is 4.14 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info