6. Residual risks
Even if you use this electric power tool in ac-
cordance with instructions, certain residual
risks cannot be rules out. The following hazards
may arise in connection with the equipment’s
construction and layout:
Lung damage if no suitable protective dust mask
is used.
Damage to hearing if no suitable ear protection is
used.
Health damage caused by hand-arm vibrations if
the equipment is used over a prolonged period or is
not properly guided and maintained.
7. Technical Data
Mains connection 230-240 V~ 50Hz
Power consumption 1400W
Weight (incl. all parts) 6.2 kg
Safety class II
Degree of protection IPX5
Inow temperature (T in
max) 50°C
Inow pressure (p in max) 0,4 MPa (4 bar)
Operating pressure (p) 7 MPa (70 bar)
Max. operating pressure (p
max)
10.5 MPa (105
bar)
Pumping rate, water 5 l/min
Max. pumping rate, water 6.2 l/min
Sound pressure level (LpA)80 dB(A), KpA 3 dB
Sound power level (LWA)96 dB(A), KWA 3 dB
Vibration (ah)≤ 2.5 m/s2
The operating conditions during measuring and the
procedures used for measuring in accordance with EN
60335-2-79.
Technical and optical changes can be carried out in the
course of further
development without notice. All dimensions, references
and information of this instruction manual are therefore
without guarantee.
leaving it unattended.
In order to prevent a hazard due to unintentional re-
setting of the
protective temperature limiter, the device should not
be supplied with
power via an external switching device, for example
a timer, or connected to a power source that is regu-
larly switched on and off by a device.
To avoid accidents and injuries from electric
shocks:
The plug and socket of an extension cable must
be watertight! Unsuitable extension cables can be
dangerous as people can be harmed by an electric
shock!
Protect the electric plug connections against
moisture.
If there is a risk of ooding, x the plug connections
in an area that is safe from ooding.
Ensure that the mains voltage matches the
speciications on the rating plate.
The electrical installation shall be according to
national wiring rules.
The device must only be connected to a mains
socket via a residual-current circuit breaker (RCD)
with a rated leakage current of not more than 30
mA. Fuse: at least 13 ampere.
Before each use, check the equipment, cable and
plug for damage.
If the power cable for this equipment is damaged, it
must be replaced by the manufacturer, a customer
service agent of the same or a similarly qualied
person in order to prevent hazards.
Do not pull the plug from the socket by the cable.
Protect the cable from heat, oil and sharp edges.
Do not carry or x the equipment by the cable.
Use only extension cables that are protected from
spray water and designed for outdoor use. Always
fully unroll a cable drum before use. Check the
cable for damage.
WARNING! Pull out the mains plug before all work
on the device, during the cleaning or maintenance
or when replacing parts or when converting the
machine for another function, in work breaks and
when not in use.
The cross-section of the power supply cable must
not be less than 2x2.5mm².
Wear sturdy footwear to protect against electric
shock.
It is recommended that the power supply for this
machine is connected via a residual current device
that interrupts the energy supply as soon as the
ground fault current exceeds 30 mA for 30 ms or
that has an earth tester.
19


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Scheppach HCE1450 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Scheppach HCE1450 in the language / languages: English, German as an attachment in your email.

The manual is 1.92 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info