Warning! Wear safety boots and tight-tting clothes in
order to prevent injuries.
Before commissioning, it is important that you know
and follow the safety notices
Observe national stipulations during work when
using the auger on public property or paths.
Keep adults, children and animals away from the
hazardous area.
Check the working environment for foreign bodies
and remove them.
When leaving the machine, the motor must always
be turned off.
Check the earth auger for correct functioning and
its safe operating condition.
Do not work by yourself, someone has to be close
in case of emergencies.
Hold on to the earth auger with both hands when
working.
Ensure you have a safe position, during the drilling
process as well.
Do not lean too far forwards when working.
Check for a awless idling mode. The auger must
not rotate in idling mode when the motor is warm.
Immediately turn off the motor when you can feel
changes to the machine‘s behaviour.
Do not place the hot auger in dry grass or on am-
mable objects (re risk!).
Drill the hole in the ground in several sections so
you can remove the soil in between.
Keep the auger vertical, do not twist it!
Always secure bore holes, otherwise there is a risk
of injury!
Exclusively drill holes in soil with the earth auger.
Other applications are not permitted.
Starting the motor: (Fig. 3)
If the motor is cold, turn the choke lever (C) to
the position.
If the motor is warm, turn the choke lever (C) to
the position.
Prime the fuel pump (16) by pressing it several
times until you can see fuel in the pump.
Put the stop switch (11) in the „start“ position.
Lightly pull on the starter cord (9) until you can
feel resistance, then pull on the cord strongly 2-3
times until the motor res briey.
CAUTION!: Do not pull out the starter cable more
than approx. 50 cm, and lead it back by hand. For ef-
cient starting, it is important to pull the starter cable
quickly and powerfully.
Turn the choke lever (C) to position.
Pull the starter cord 2-3 times again until the mo-
tor res and runs in idle mode.
Warning! The earth auger only begins to rotate
when the throttle lever is used.
Stop the engine
Press the stop switch (11) in the ‘Stop’ position.
When restarting, rst press the stop switch (11) back
to the ‘Start’ position.
Before starting the motor, check the following:
Fuel level - the fuel tank should be at least half full
Condition of the fuel lines
Outer screw couplings for tight t
The earth auger has to be able to run freely
Operating
Set the auger down and actuate the throttle con-
trol lever (13).
Adjust the power according to the ground condi-
tions in order to be able to proceed ideally.
If the ground condition is ideal, permitting a stea-
dy work speed, using the adjusting screw, you
can lock the throttle control lever (13) (in the cen-
tre position) in order to make your work easier.
When leaving the auger, the motor must always
be turned off.
9. Cleaning and maintenance
Cleaning
We recommend that you clean the device immedi-
ately each time you have nished using it.
Clean the equipment regularly with a moist cloth
and some soft soap. Do not use cleaning agents
or solvents; these could attack the plastic parts of
the equipment. Ensure that no water can seep into
the device.
Maintenance
For all work on the machine, the spark plug cap and
the spark plug have to be removed (high voltage).
Please adhere to the maintenance schedule.
Daily before beginning work
Check fuel tank and fuel lines for tightness.
Check mounting parts, exhaust cover, air lter cover,
oil, position of the auger and functioning of the ope-
rating elements.
After 20 operating hours
Clean air lter and check spark plug
After 100 operating hours
Clean fuel tank and replace spark plug
After 300 operating hours
Replace air lter
Important notice in the event of repairs:
When sending earth augers to be repaired, please
note that, for safety reasons, they must be delivered
to the service station free from oil and petrol.
Warning! No smoking and no open re.
Risk of explosion.
Air lter, Fig. 4-5
Regular cleaning of the air lter prevents carburettor
malfunctions.
Cleaning the air lter and replacing the air lter insert:
Loosen the screw (E) on the air lter casing (3), re-
move the air lter cover and check it.
Replace the damaged element.
Clean dirt from the inside of the lter casing with a
clean, damp cloth.
Carefully remove the foam lter insert (F) and
check it for damage, replace if required.
Clean the foam lter insert (F) in warm water and
with a mild soap solution. Thoroughly rinse it with
clear water and leave it to dry.
21


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Scheppach EA1700H Herkules at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Scheppach EA1700H Herkules in the language / languages: English, German, French, Italian, Spanish, Finnish as an attachment in your email.

The manual is 3.95 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info