781410
35
Zoom out
Zoom in
Previous page
1/200
Next page
www.scheppach.com / service@scheppach.com / +(49)-08223-4002-99 / +(49)-08223-4002-58
GB | 35
AC motor
The mains voltage must be 230 V~.
Extension leads up to 25 m in length must have a
cross-section of 1.5 mm2. Extension leads whose
length is over 25 m must have a cross-section of
at least 2.5 mm2.
Connections and repairs of electrical equipment may
only be carried out by an electrician.
Please provide the following information in the event
of any enquiries:
Type of current for the motor
Machine data - type plate
Machine data - type plate
13. Disposal and recycling
The equipment is supplied in packaging to preven it
from being damaged in transit. The raw materials in
this packaging can be reused or recycled. The equip-
ment and its accessories are made of various types
of material, such as metal and plastic. Defective
components must be disposed of as special waste.
Ask your dealer or your local council.
Old devices must not be disposed of with house-
hold waste!
This symbol indicates that this product must
not be disposed of together with domestic
waste in compliance with the Directive
(2012/19/EU) pertaining to waste electrical
and electronic equipment (WEEE). This product must
be disposed of at a designated collection point. This
can occur, for example, by handing it in at an author-
ised collecting point for the recycling of waste elec-
trical and electronic equipment. Improper handling
of waste equipment may have negative consequenc-
es for the environment and human health due to po-
tentially hazardous substances that are often con-
tained in electrical and electronic equipment. By
properly disposing of this product, you are also con-
tributing to the effective use of natural resources.
You can obtain information on collection points for
waste equipment from your municipal administration,
public waste disposal authority, an authorised body
for the disposal of waste electrical and electronic
equipment or your waste disposal company.
12. Electrical Connection
The installed electric motor is connected and is ready
to work. The connection complies with the relevant
VDE and DIN regulations.
The customer-side mains supply and the used exten-
sion line must meet these regulations.
The product meets the requirements of EN 61000-
3-11 and is subject to special connection condi-
tions. This means that use of the product at any
freely selectable connection point is not allowed.
Given unfavorable conditions in the power supply
the product can cause the voltage to uctuate tem-
porarily.
The product is intended solely for use at connec-
tion points that
a) do not exceed a maximum permitted supply im-
pedance “Z, or
b) have a continuous current-carrying capacity of
the mains of at least 100 A per phase.
As the user, you are required to ensure, in consul-
tation with your electric power company if neces-
sary, that the connection point at which you wish to
operate the product meets one of the two require-
ments, a) or b), named above.
Important information
In the event of an overloading the motor will switch
itself off. After a cool-down period (time varies) the
motor can be switched back on again.
Defective Electric Connection Lines
Often, insulation damages occur on electrical con-
nection lines.
Causes are:
Drag marks if connection lines are led through win-
dow or door clearances.
Kinks due to improper attachment or routing of the
connection line.
Cuts caused by running over the connection line.
Insulation damages caused by pulling the connec-
tion line out of the wall socket.
Fissures caused by the ageing of the insulation.
Such defective electric connection lines must not be
used and are hazardous due to the insulation dam-
ages.
Regularly check the electrical connection lines for
damages. Please make sure that the connection
lines are disconnected from the mains supply during
the check.
Electrical connection lines must comply with the rel-
evant VDE and DIN regulations. Only use connection
lines labelled with H05VV-F. The labelling of the con-
nection cable with the type specication is required.
35


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Scheppach CSE2500 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Scheppach CSE2500 in the language / languages: English, German, Dutch, French, Italian, Polish, Spanish as an attachment in your email.

The manual is 8.36 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info