4.1 Battery functions
6-cell lead acid or lead gel batteries, 55 Ah and above
Simultaneous charging of the starter battery and the living area battery via
the alternator, parallel connection of the batteries via a cut-off relay
The battery cut-off (at the battery cut-off switch of the Electrobloc, see Fig.
4, Pos. 15, see also section 3.4) isolates the following connections from the
living area battery:
F all 12 V consumers
F the frost protection valve
This prevents slow discharge of the living area battery by the standby cur-
rent during shutdown of the vehicle (discharge with approx. 4 Ah in month).
The batteries can still be charged using the Electrobloc, the alternator, an
auxiliary charging unit or the solar charge regulator, even when the battery
cut-off switch is switched off.
The switching option provided by the battery selector switch ensures opti-
mum charging of the two battery types, lead gel and lead acid.
The battery monitor of the DT ... control and switch panel constantly moni-
tors the living area battery with dynamic voltage threshold. Lower discharge
currents cut off ”earlier than with larger currents. This provides improved to-
tal discharge protection. Monitoring is also performed in the switched-off
state. A warning message is displayed below 12.0 V (dependent on current
drain).
If the voltage of the living area battery sinks further, falling below 10.5 V, the
battery monitor immediately switches off all 12 V consumers. The control
and switch panel also switches itself off. Only the frost protection valve con-
tinues to be powered (so it stays closed). Before switch-off, all switch states
and the value of the battery capacity are stored and restored after power-on.
If an overload or an insufficiently charged living area battery causes the vol-
tage to fall so low that the automatic disconnector is triggered, any non-es-
sential consumers should be switched off.
If need be, the 12 V supply can begin operation for a short time. In this case
the 12 V main switch on the DT ... control and switch panel must be swit-
ched on.
However , if the battery voltage remains below 11.0 V, the 12 V power supply
can not be turned back on.
Fully charge the living area battery as soon as possible. For more informa-
tion, see the ”Battery voltages” description in the associated DT ... control
and switch panel instruction manual.
Suitable batteries
Battery charging
during mobile operation
Battery isolation
Battery selector switch
Battery monitor w ith
automatic disconnect
10


Need help? Post your question in this forum.

Forumrules
1

Forum

schaudt-elektroblock-ebl-101-c

Reset search

  • Jag äger en Detleffs husbil med elekronikskåp EBL101. Jag använder ett AGM-batteri till bodelen. Hur skall batteri-väljaren ställas på elektronikskåpet? Bly eller Gel?
    Tack! Submitted on 20-10-2021 at 10:11

    Reply Report abuse
  • Hi
    Got a electroblock 101 on a Hymer and it doesn't seem to be charging
    Also the AES does not work on 12 v could you tell me if there is
    A problem with the electroblock
    Regards Submitted on 11-9-2021 at 21:26

    Reply Report abuse


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Schaudt Elektroblock EBL 101 C at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Schaudt Elektroblock EBL 101 C in the language / languages: English as an attachment in your email.

The manual is 0,62 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Schaudt Elektroblock EBL 101 C

Schaudt Elektroblock EBL 101 C User Manual - German - 16 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info