Instruction Manual Electrobloc EBL 101 C
8
Date: 30.09.2008 811.553 BA / EN
³ F ully charge the living area battery before closing down t he system.
The living area battery is then protected against total discharge. This only
applies if the battery is intact. Follow the instructions of the battery manufac-
turer. The shut down system requires approx. 4 Ah per month.
Disconnect the living area battery from the 12 V power supply if the motor-
home is not used for a longer period (during the winter for example). For
this, the system has a battery cut-off mechanism that isolates the living area
battery from the vehicle. Battery isolation is activated from the DT ... control
and switch panel (see DT ... control and switch panel instruction manual).
³ 12 V main switch on the DT ... control and switch panel must be switched
off.
³ Move battery cut-off switch (sliding switch, see Fig. 4, Pos. 15) to posi-
tion ”Battery OFF”.
The battery cut-off switch isolates the following connections from the living
area battery:
F 12 V consumers
F Frost protection valve
F Control and switch panel
Y The living area battery can also be charged using the internal charger
module, an auxiliary battery charging unit, the solar charge regulator and
the alternator when the battery cut-off switch is switched off.
³ F ully charge the living area battery before closing down t he system.
³ Remove the ”+ solar cell” connector on the solar charge regulator .
³ Remove the clamps from the battery poles.
Y The battery alarm is no longer active.
Y The frost protection valve opens for certain heater systems when the li-
ving area battery is isolated from the Electroblock via the battery cut-off.
The boiler and water tank empty when the frost protection valve is open.
For more information, see the instruction manual of the heater system.
4 Application and Functions in Detail
Y This device is intended solely for installation in a vehicle.
The EBL 101 C is the central energy supply unit for all 12 V consumers in
the electrical system on board the motorhome or caravan. It is normally fit-
ted inside a cabinet or a stowage space and can be accessed from the front
to change a fuse.
Shutdown of system up
to 6 months
Disconnect the living
area battery from the
12 V power supply
Shutdown period longer
than 6 months
8


Need help? Post your question in this forum.

Forumrules
1

Forum

schaudt-elektroblock-ebl-101-c

Reset search

  • Jag äger en Detleffs husbil med elekronikskåp EBL101. Jag använder ett AGM-batteri till bodelen. Hur skall batteri-väljaren ställas på elektronikskåpet? Bly eller Gel?
    Tack! Submitted on 20-10-2021 at 10:11

    Reply Report abuse
  • Hi
    Got a electroblock 101 on a Hymer and it doesn't seem to be charging
    Also the AES does not work on 12 v could you tell me if there is
    A problem with the electroblock
    Regards Submitted on 11-9-2021 at 21:26

    Reply Report abuse


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Schaudt Elektroblock EBL 101 C at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Schaudt Elektroblock EBL 101 C in the language / languages: English as an attachment in your email.

The manual is 0,62 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Schaudt Elektroblock EBL 101 C

Schaudt Elektroblock EBL 101 C User Manual - German - 16 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info