734407
9
Zoom out
Zoom in
Previous page
1/12
Next page
9
>
check there is 230 V AC :
at the supply
at the appliance plug
>
then check : the connections to the ignition PCB
the fuse on the PCB
the thermistor connections
the flow sensor connections
>
check that the gas supply is turned on
>
check that there is sufficient gas pressure to the
heater
>
check that the gas supply is turned on
>
check that there is suffient gas pressure to the heater
>
change gas valve
>
change main PCB
>
Correct live and neutral connections to the heater
>
change ignition PCB
>
incorrectly fitted or obstructed flue
>
check connections to the air pressure switch and
that the tubes are not blocked or spilt :
>
check air pressure switch : change if necessary
>
check electrode lead : change if necessary
>
check flame sense lead : change if necessary
>
change ignition PCB
>
change main PCB
no electrical supply
no gas flow
gas valve
reversed
live and neutral
flue system
ignition system
the water-heater will not run but
the safety indicator light is not lit
the water-heater will not run =
safety disconnection
the spark train does not light the
burner = safety disconnection
The burner lights for less than 10
seconds, then goes out
there is no spark train then the fan
runs = safety disconnection
fault
cause >
remedy
>
change temperature sensor
>
change main PCB
>
heat exchanger blocked : descale or replace
>
change temperature sensor
>
change main PCB
>
change gas valve
electrical circuit
water circuit
electrical circuit
water too hot = safety discon-
nection
water is not hot enough (maxi-
mum temp 50°C at 5 l/min con-
trol at max)
FAULT FINDING
Downloaded from www.Manualslib.com manuals search engine
9


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Saunier Duval OPALIA X13 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Saunier Duval OPALIA X13 in the language / languages: English as an attachment in your email.

The manual is 0,53 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info