E2 Code
Water tank full when cooling.
Take off the rubber stopper and empty
the water.
E3 Code
Evaporator temperature sensor failed.
Replace evaporator temperature sensor.
Contact authorized service technician
for repair.
TECHNICAL DATA
Notice: Operation temperature range:
Maximum cooling
Minimum cooling
Dry bulb temperature /
Wet bulb temperature()
35/24
18/12
Below data for your operating reference
Model
PAC-125773
Rated voltage
220-240V
Rated frequency
50Hz
Rated input
1000W
Rated current
4.5A
Cooling capacity
2600W (9000Btu/h)
Moisture removal (L/H)
1.0
Air flow
320m³/h
ERP INFORMATION
Value
Trademark
Sauber
Model identification
PAC-125773
Sound power (cooling)
65dB(A)
Name of refrigerant
R290 (0.16kg)
Rated power input for cooling (kW)
1.0
Rated energy efficiency ratio
2.6
GWP (kgCO2eq)
3
Energy efficiency class
A
Energy consumption for double ducts appliances (kWh/h)
N.A
Energy consumption for single duct appliances (kWh/h)
1.0
Power consumption in thermostat-off mode (W)
N.A
Power consumption in stand-by mode (W)
0.5W
Cooling capacity
2600W
Refrigerant leakage contributes to climate change. Refrigerant with lower global warming potential (GWP)
would contribute less to global warming than a refrigerant with higher GWP, if leaked to the atmosphere.
This appliance contains a refrigerant fluid with a GWP equal to 3. This means that if 1 kg of this refrigerant
fluid would be leaked to the atmosphere, the impact on global warming would be 3 times higher than 1 kg
of CO2, over a period of 100 years. Never try to interfere with the refrigerant circuit yourself or disassemble
the product yourself and always ask a professional.
#Energy consumption 1.0 kWh for model PAC-125773 in 60 minutes of use under standard test conditions.
The actual energy consumption depends on how the device is used and where it is located.
For any additional information, please contact:
31


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Sauber PAC-125773 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Sauber PAC-125773 in the language / languages: English, German, Dutch, French as an attachment in your email.

The manual is 2.56 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info