- 29 -
Continuous Drainage
Under normal use, the unit can evaporate the condensate water automatically by the splash motor. If the
water splash motor is damaged, continuous drainage (drain the water from the bottom outlet) can be used
manually. Under this condition, the water full indicator will light up. Please remove the rubber boot and then
the rubber stopper from the drainage outlet and connect a drain hose to the outlet, then all the water in the
water tank will be drained out. The unit can also work well. But in order not to decrease the efficiency of the
performance, please contact authorized service technician to repair the splash motor as soon as possible.
When you plan to leave this unit unused for a long time, please also remove the rubber stopper from the
drainage outlet at the bottom of unit, and drain out all the water.
CLEANING AND MAINTENANCE
Before cleaning, be sure to disconnect the appliance from any electric supply outlet.
Do not use gasoline or other chemicals to clean the appliance.
Do not wash the appliance directly.
If the appliance is damaged, please contact the dealer or repair shop.
Air Filter
If the air filter becomes clogged with dust/dirt, the air filter should be cleaned once every two weeks.
- Pull out the air filter from the air inlet grille by the pull tab.
- Clean the air filter with neutral detergent in lukewarm water (40℃) and dry it up in the shade.
- Insert the air filter back into the air inlet grille; replace the components as they were.
Clean the Surface
First clean the surface with a neutral detergent and wet cloth, and then wipe it with a dry cloth.
TROUBLESHOOTING