SATEL VERSA IP 33
6.21.7 Checking the firmware version of modules
Enter the user menu and press in turn . Information on the firmware of
module with the lowest address will be displayed: the module name in the upper line, and the
firmware version and build date in the lower line. You can scroll through the list of modules
using the and keys. In the case of the built-in Ethernet module, pressing the
or key will display additional information (IP address, MAC address, individual
identification number for the purpose of communication via the SATEL server [ID]).
6.21.8 Checking the current supply voltage in modules
Not all modules provide information on the current voltage.
Enter the user menu and press in turn . Information on supply voltage of
the lowest address module will be displayed. To scroll through the list, use the arrow keys.
6.21.9 Outputs reset
Use the function to:
deactivate 5. “DURESS” ALARM, 14. CHIME or 15. CONTROLLED function outputs (if the cut-
off time equal to 0 is programmed by the installer for such an output, the output can only
be deactivated in this manner),
deactivate for 16 seconds the 11. FIRE DETECTORS POWER SUPPLY function output (to clear
the alarm memory of fire detectors),
activate the 21. DETECTORS RESETTING function output.
Enter the user menu and press in turn .
6.22 Service
The functions related to control panel programming (starting local or remote programming)
are described in the PROGRAMMING manual.
6.22.1 Defining the service access rules
Enter the user menu and press in turn . In the upper line of the display, the
function name will be presented, and in the lower one – the first of the available options. You
can scroll through the list using the and keys. The following symbol is situated in
the upper right corner of the display:
– option is enabled,
– option is disabled.
Press any number key to enable/disable the option.
If you want to see the status of all options, press
or . The numbers around the
display allow the options to be identified. Use the
and keys to move the cursor.
To enable/disable an option, hover the cursor over it and press any numeric key. If you want
to restore the previous way of presentation of the list of options, press or .
Press to confirm the changes made and quit the function.
Description of the options
The order of describing the options corresponds to their numeration in the keypad.
Permanent access – if the option is enabled, the service code can be used to get access to
the alarm system at all times.
If the alarm system is to meet requirements of the EN 50131 standard for
Grade 2, the service code access should be time limited.
35


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Satel Versa IP at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Satel Versa IP in the language / languages: English as an attachment in your email.

The manual is 0,76 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Satel Versa IP

Satel Versa IP Quick start guide - English - 11 pages

Satel Versa IP User Manual - English - 32 pages

Satel Versa IP Installation Guide - English - 36 pages

Satel Versa IP Additional guide - English - 93 pages

Satel Versa IP Quick start guide - German - 11 pages

Satel Versa IP Additional guide - German - 97 pages

Satel Versa IP User Manual - German - 45 pages

Satel Versa IP Installation Guide - German - 38 pages

Satel Versa IP Quick start guide - Dutch - 2 pages

Satel Versa IP User Manual - Dutch - 45 pages

Satel Versa IP Quick start guide - Dutch - 12 pages

Satel Versa IP Additional guide - Dutch - 93 pages

Satel Versa IP User Manual - Dutch - 45 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info