629722
83
Zoom out
Zoom in
Previous page
1/93
Next page
SATEL VERSA IP 81
Right – defines which functions are available to the user. The following rights are available:
Arming – the user can arm the system.
Disarming – the user can disarm the system.
Alarm clearing – the user can clear alarms.
Tel. mess. clearing – the user can cancel messaging by means of the ABORT V.MSG. user
function (if he has at same time the ALARM CLEARING right and the CLEAR MESSAGING ON
ALARM CLEARING
global option is enabled, the messaging will be automatically canceled
when the alarm is cleared).
Auto-arming defer – using the A-ARM DEFER. function ([CODE] 6. SETTINGS
1. A-ARM DEFER.), the user can defer arming by the timer.
Zone inhibition – the user can inhibit the system zones by means of the INHIBIT function
([CODE] 4. BYPASSES 1. INHIBIT).
Zone isolation – using the ISOLATE function ([CODE] 4. BYPASSES 1. ISOLATE),
the user having additionally the Z
ONE INHIBITION right can isolate the system zones.
Change access code – the user can change own access code (C
HANGE CODE function).
Users editing – the user can add, edit and delete users (USERS function).
Control – the user can control the outputs by means of the CONTROL function.
Programming – the user has access to the SETTINGS function, which allows him to
program the control panel clock, timers, telephone numbers for messaging and codes to
clear messaging.
DOWNLOAD/SERVICE – the user can define the rules of service access, initiate remote
programming of the control panel from the keypad and replace batteries in the wireless
keypads.
Inspection – the user has access to the EVENT LOG and SYSTEM STATE functions. In case
of arming by means of the LCD keypad, the user gets information about bypassed
zones and causes of denial of arming, if any (the user can enforce the arming).
Tests – the user has access to the TESTS submenu.
DURESS – a special right that allows to define in the system a code/card which, if used for
arming/disarming or alarm clearing, will trigger a silent alarm (which is signaled in no
way, but the alarm code is sent to the monitoring station). The alarm will be triggered in
the partition in which alarm would be triggered in the event of tamper of the
keypad/proximity card arm/disarm device used for arming/disarming or alarm clearing.
INT-VG access – the user can operate the control panel by means of a telephone
(DTMF), using the interactive voice menu.
13.3 Functions assigned to keyfob buttons
Functions that can be assigned to the keyfob buttons are numbered, which makes easier
their programming in the keypad (you can also scroll through the list using the and
keys).
In the LED keypad, the function number is presented in binary form on the LEDs 1-12, in the
same way as the decimal values (see: page 10 Table 4). Only values corresponding to the
function numbers can be entered.
0. Not used
1. Zone 1 violation
2. Zone 2 violation
3. Zone 3 violation
83


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Satel Versa IP at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Satel Versa IP in the language / languages: English as an attachment in your email.

The manual is 1,31 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Satel Versa IP

Satel Versa IP Quick start guide - English - 11 pages

Satel Versa IP User Manual - English - 32 pages

Satel Versa IP Installation Guide - English - 36 pages

Satel Versa IP User Manual - English - 43 pages

Satel Versa IP Quick start guide - German - 11 pages

Satel Versa IP Additional guide - German - 97 pages

Satel Versa IP User Manual - German - 45 pages

Satel Versa IP Installation Guide - German - 38 pages

Satel Versa IP Quick start guide - Dutch - 2 pages

Satel Versa IP User Manual - Dutch - 45 pages

Satel Versa IP Quick start guide - Dutch - 12 pages

Satel Versa IP Additional guide - Dutch - 93 pages

Satel Versa IP User Manual - Dutch - 45 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info