74 VERSA IP SATEL
station. You can program a number of days, hours, minutes and seconds between the
transmissions. Entering zeros only means that no additional transmission will be sent.
11.5 Event codes
For the pulse and Ademco Express formats, it is necessary to program codes which will be
reported to the monitoring station if the defined events occur. An event code consists of 2
hexadecimal characters (digits or letters from A to F). The reported events are those for
which a code different from “00” has been programmed.
For the Contact ID and SIA formats, event codes consistent with format specification are
sent. In case of the CONTACT ID (SELECTED) and SIA (SELECTED), the codes must be
programmed at the events which are to be reported (not the programmed code, but a code
consistent with the format specification will be sent).
11.6 Starting the reporting
1. Get the data necessary to properly start the reporting from the monitoring station
operator:
depending on the transmission path:
telephone number of the monitoring station (reporting via telephone line),
server address, TCP port number, STATION KEY and ETHM KEY (reporting via
Ethernet network).
transmission format required by the monitoring station,
identifiers assigned to the alarm system,
list of event codes (not applicable to Contact ID and SIA formats).
2. Determine whether the event codes will be sent to both monitoring stations or to one of
them only (enable one of the options: STATION 1 OR 2, STATION 1, STATION 2 or STATION 1
AND
2).
3. Determine whether the number of events from the same source is to be limited (EVENTS
AMOUNT LIMITING
option).
4. Determine when the restore code is to be sent (RESTORE AFTER BELL, RESTORE AFTER
DISARM
options).
5. For the monitoring station to which event codes are to be sent:
define the format in which event codes will be sent (REPORTING FORMAT parameter),
if you select Ademco Express, Contact ID or SIA format, configure the additional
options (SIA SEND PART. NAME, SIA SEND SOURCE NAME, SIA CONFIRM EACH BLOCK,
SIA ID. CONF. REQUIRED, LONGER WAITING FOR INITIAL HANDSHAKE, LONG KISS-OFF
SIGNAL
),
program the identifiers to be sent with the event codes,
for the SIA or TELIM format, if the identifier is to consist of 6 characters, program SIA /
TELIM PREFIX.
6. Define the parameters of test transmissions.
7. If a transmission format other than CONTACT ID (FULL) or SIA (FULL) is selected, program
the codes for events which are to be reported.
8. Define priority of the transmission paths to be used by the control panel.
11.6.1 Reporting via telephone line
1. Enable the REPORTING TELEPHONE option (see: “Global options” p. 27).
76


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Satel Versa IP at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Satel Versa IP in the language / languages: English as an attachment in your email.

The manual is 1,31 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Satel Versa IP

Satel Versa IP Quick start guide - English - 11 pages

Satel Versa IP User Manual - English - 32 pages

Satel Versa IP Installation Guide - English - 36 pages

Satel Versa IP User Manual - English - 43 pages

Satel Versa IP Quick start guide - German - 11 pages

Satel Versa IP Additional guide - German - 97 pages

Satel Versa IP User Manual - German - 45 pages

Satel Versa IP Installation Guide - German - 38 pages

Satel Versa IP Quick start guide - Dutch - 2 pages

Satel Versa IP User Manual - Dutch - 45 pages

Satel Versa IP Quick start guide - Dutch - 12 pages

Satel Versa IP Additional guide - Dutch - 93 pages

Satel Versa IP User Manual - Dutch - 45 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info