629722
51
Zoom out
Zoom in
Previous page
1/93
Next page
SATEL VERSA IP 49
DLOADX server – address of the computer with DLOADX program. If the computer is not in
the same local network as the control panel, it must be a public address. You can enter
either the IP address or the domain name.
Port – number of the TCP port used for communication between control panel and
a computer with DLOADX program via Ethernet. You can enter values from 1 to 65535.
Default value: 7090.
DLOADX key – a string of up to 12 alphanumeric characters (digits, letters and special
characters) which is used for data encryption during communication between control panel
and computer with DLOADX program via Ethernet.
SATEL service
LAN [SATEL server LAN] – if this option is enabled, the control panel connects to the SATEL
server via the Ethernet module, while the SATEL server makes it possible to establish
communication with the control panel. For communication vie the SATEL server, you do
not need to additionally configure the network device through which the module connects
to the public network.
For establishing communication with the SATEL server, the DNS server must be used.
For communication via the SATEL server, the ports of 1024-65535 range are used as
outgoing ports. These ports must not be blocked.
Do not report SATEL server connection trouble [No SATEL trbl.] – if this option is
enabled, loss of communication with the SATEL server will not be reported.
Communication with mobile application [Mobile app.] – if this option is enabled,
communication with the control panel can be established from the mobile application. The
option is available if the LAN option is enabled.
Alarm 3 incorrect codes (mobile application) [Al.3 wrong codes] – if this option is enabled,
entering an invalid code three times from the VERSA CONTROL application will trigger an
alarm.
Push notifications – if this option is enabled, the VERSA CONTROL application can provide
information about alarm system events by means of push notifications.
MAC – information on module hardware address.
ID – information on individual identification number for the purpose of communication via the
SATEL server (programming by means of DLOADX program, operating by means of
VERSA CONTROL application). The ID number is assigned automatically by the SATEL
server.
If the control panel is to be used in another alarm system, the hitherto used ID number
must be deleted. It can be done from the keypad, when programming the built-in
Ethernet module, in the last step, if the control panel is connected to the SATEL
server. Having deleted the old ID number, the control panel will receive a new one.
The VERSA CONTROL applications using the old ID number will be unable to connect
to the control panel.
IP – information on the module local / public address.
QR-code – pressing the button will display the “QR-code” window. The window shows the
QR code containing information required when configuring settings of the VERSA
CONTROL application. You can read the QR code by using a mobile device or export to
file and transmit to the users. The QR code facilitates configuring the VERSA CONTROL
application settings.
Refresh – pressing the button will update information presented in the MAC, ID and IP fields.
51


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Satel Versa IP at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Satel Versa IP in the language / languages: English as an attachment in your email.

The manual is 1,31 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Satel Versa IP

Satel Versa IP Quick start guide - English - 11 pages

Satel Versa IP User Manual - English - 32 pages

Satel Versa IP Installation Guide - English - 36 pages

Satel Versa IP User Manual - English - 43 pages

Satel Versa IP Quick start guide - German - 11 pages

Satel Versa IP Additional guide - German - 97 pages

Satel Versa IP User Manual - German - 45 pages

Satel Versa IP Installation Guide - German - 38 pages

Satel Versa IP Quick start guide - Dutch - 2 pages

Satel Versa IP User Manual - Dutch - 45 pages

Satel Versa IP Quick start guide - Dutch - 12 pages

Satel Versa IP Additional guide - Dutch - 93 pages

Satel Versa IP User Manual - Dutch - 45 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info