5. For the monitoring station to which event codes are to be sent:
define the format in which event codes will be sent (REPORTING FORMAT parameter),
if you select Ademco Express, Contact ID or SIA format, configure the additional
options (SIA SEND PART. NAME, SIA SEND SOURCE NAME, SIA CONFIRM EACH BLOCK,
SIA ID. CONF. REQUIRED, LONGER WAITING FOR INITIAL HANDSHAKE, LONG KISS-OFF
SIGNAL
),
program the identifiers to be sent with the event codes,
for the SIA or TELIM format, if the identifier is to consist of 6 characters, program SIA
/
TELIM PREFIX.
6. Define the parameters of test transmissions.
7. If a transmission format other than CONTACT ID (FULL) or SIA (FULL) is selected, program
the codes for events which are to be reported.
10.5.1 Reporting via telephone line
1. Enable the REPORTING TELEPHONE option (see: “Global options” p. 27).
2. Program the monitoring station parameters:
– phone number,
the number of attempts to connect to the station after which, if there is no connection,
the control panel will suspend reporting,
– time for which reporting will be suspended after the programmed number of attempts to
establish connection with the station has been made.
3. Configure the global options for telephone communicator:
determine how the telephone numbers should be dialed (TONE DIALING; in case of the
pulse dialing option – PULSE 1/1,5 (OFF 1/2)),
determine whether the control panel, prior to dialing the number, should check the
telephone line for dialing signal (NO DIAL TONE TEST),
determine the reaction to signals received after dialing the number (NO ANSWER TONE
TEST
).
10.5.2 Reporting via Ethernet network
1. Enable the REPORTING ETHM option (see: “Global options” p. 27).
2. Program the monitoring station parameters:
monitoring station address,
– TCP port,
data encryption key (STATION KEY),
control panel identifier for the purposes of monitoring via Ethernet (ETHM KEY).
3. Define whether the events are to be sent in SATEL format or SIA-IP format (IP FORMAT).
4. If the SIA-IP format is to be used, configure the additional options and parameters (SEND
MAC ADDRESS, SEND TIMESTAMP, ENCRYPT DATA, SIA-IP KEY, HEX, SIA-IP ACCT and
SUPERVISION INTERVAL).
5. Specify whether TCP or UDP protocol is to be used.
6. Configure the Ethernet module network settings.
11. Messaging
The control panel can send notifications about system events by phone or by means of
e-mail messages.
75


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Satel VERSA 10 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Satel VERSA 10 in the language / languages: English as an attachment in your email.

The manual is 1,13 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Satel VERSA 10

Satel VERSA 10 Quick start guide - English - 11 pages

Satel VERSA 10 Installation Guide - English - 36 pages

Satel VERSA 10 User Manual - English - 32 pages

Satel VERSA 10 User Manual - English - 42 pages

Satel VERSA 10 Quick start guide - German - 11 pages

Satel VERSA 10 Additional guide - German - 89 pages

Satel VERSA 10 User Manual - German - 44 pages

Satel VERSA 10 Installation Guide - German - 37 pages

Satel VERSA 10 Quick start guide - German - 2 pages

Satel VERSA 10 Quick start guide - Dutch - 11 pages

Satel VERSA 10 User Manual - Dutch - 44 pages

Satel VERSA 10 Quick start guide - Dutch - 2 pages

Satel VERSA 10 Additional guide - Dutch - 86 pages

Satel VERSA 10 Installation Guide - Dutch - 35 pages

Satel VERSA 10 Quick start guide - Dutch - 2 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info