699075
95
Zoom out
Zoom in
Previous page
1/114
Next page
SATEL INTEGRA 93
the timer start/end time when an exception applies.
If a year is programmed for an exception, the setting will only be valid for the current
year. If no year is programmed (the 9999 sequence is entered in the keypad instead of
the year), the exception will be valid every year.
Arming mode the arming mode which will be activated when the timer starts (in the
DLOADX program, enter an additional digit next to the timer start time: 0 full arming; 1
full arming + bypasses; 2 arming without interior; 3 arming without interior and without
entry delay).
11. User schedules
User schedules should be defined for the needs of the SCHEDULE type users (see: USER
MANUAL
). You can program the user schedules:
using the keypad, in the service mode, by means of the functions available in the USER
SCHEDULES
submenu,
using the DLOADX program, in the Timerswindow, User Schedulestab.
For each user schedule, you can:
program an individual name (up to 16 characters),
indicate the timers which will determine when the user will have access to the system.
12. Reporting
The control panel can send event codes to the monitoring station using the following
transmission paths:
analog telephone line (INTEGRA 128, INTEGRA 64, INTEGRA 32 or INTEGRA 24 control
panel),
GSM voice channel (INTEGRA 128-WRL control panel) the use of this transmission path
is not recommended because of distortions that may occur when sending the event codes,
Ethernet (connection of the ETHM-1 Plus / ETHM-1 module to the control panel required),
GPRS (INTEGRA 128-WRL control panel; in case of other control panel INT-GSM module
must be installed in the alarm system or SATEL GSM module must be connected to the
control panel),
SMS (INTEGRA 128-WRL control panel; in case of other control panel INT-GSM module
is required to be installed in the alarm system) the control panel gets no
acknowledgement of event code receipt.
The control panel will try to send event code to the monitoring station using in turn:
1. ETHM-1 Plus / ETHM-1 module and/or INT-GSM module. If several such modules are
connected to the control panel, that with the lowest address will be used. Event code can
be sent via Ethernet, GPRS or SMS.
When configuring the ETHM-1 Plus module to which the INT-GSM module is
connected, or when configuring the INT-GSM module connected directly to the control
panel, define priority of the transmission paths. The transmission path which is not
included in the list defining the priority of transmission paths, will not be used.
2. GSM phone [INTEGRA 128-WRL control panel] / SATEL GSM module [any control panel]
for GPRS transmission.
3. GSM phone to send SMS [INTEGRA 128-WRL control panel],
95


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Satel Integra 64 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Satel Integra 64 in the language / languages: English as an attachment in your email.

The manual is 1,32 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Satel Integra 64

Satel Integra 64 User Manual - English - 51 pages

Satel Integra 64 Installation Guide - English - 36 pages

Satel Integra 64 Additional guide - German - 121 pages

Satel Integra 64 User Manual - German - 54 pages

Satel Integra 64 Installation Guide - German - 38 pages

Satel Integra 64 Quick start guide - German - 2 pages

Satel Integra 64 User Manual - Dutch - 52 pages

Satel Integra 64 Quick start guide - Dutch - 24 pages

Satel Integra 64 Additional guide - Dutch - 121 pages

Satel Integra 64 Installation Guide - Dutch - 35 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info