SATEL INTEGRA 85
can work within each other's operating range (12 seconds up to 150, 24 seconds up to
300, 36 seconds up to 450). Beyond the response period, information about tampers of
devices and violations of detectors operating in active mode are sent to the control panel.
The response period has an effect on the level of energy consumption by the wireless
devices. The less often communication between the control panel and the wireless devices
takes place, the lower energy consumption and the longer battery life are.
In the case of the AMD-103 detector, no communication takes place during polling.
Higher sensitivity for jamming detection if this option is enabled, the sensitivity of
detection of radio communication jamming is boosted.
Synchronize this function starts the procedure of synchronization, i.e. checking for
presence of other ABAX 2 / ABAX wireless systems working within the control panel
operating range. The control panel will synchronize the response period so that the radio
transmissions of some systems should not be mutually jammed. Synchronization is
performed automatically upon starting the control panel and after each operation of
adding/removing devices supported by it.
Test mode to carry out diagnostics / service work, you can start the test mode in the ABAX
system. When the system is running in the test mode:
detector LEDs are enabled,
tamper signaling in the sirens is blocked.
The command to start/end the test mode is sent during polling, i.e. with delay whose
duration depends on the frequency of polling. The test mode will be disabled automatically
30 minutes after:
starting the test mode from the DLOADX program (the 30-minute period is running from
the moment of exiting the system ABAX settings),
exiting the service mode in the control panel.
According to requirements of the EN50131 standard, the level of radio signals sent by
wireless devices is reduced during the test mode operation.
For the AMD-103 detector, entering the test mode remotely is not possible.
9.2 Parameters and options of wireless devices
Filter the number of consecutive response periods, during which communication with the
device failed to be established, for the loss of communication with the device to be
reported. Values from the 0 to 50 range can be entered. Entering the digit 0 will disable
control of the device presence in the system.
In the case of the AMD-103 magnetic contact, the presence check is performed in
a different way than for the other ABAX 2 / ABAX devices. If the value programmed for
the FILTER parameter differs from 0, the lack of presence will be reported if no
transmission from the AMD-103 magnetic contact is received within one hour.
Always active the option is available for the most of wireless detectors. If enabled, the
detector is permanently switched over to the active mode (see Wireless detectors p. 90).
The AMD-103 detector and the wireless detectors assigned to 24-h zones are always
in the active mode, therefore the ALWAYS ACTIVE option does not have to be enabled
for them.
87


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Satel Integra 64 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Satel Integra 64 in the language / languages: English as an attachment in your email.

The manual is 1,32 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Satel Integra 64

Satel Integra 64 User Manual - English - 51 pages

Satel Integra 64 Installation Guide - English - 36 pages

Satel Integra 64 Additional guide - German - 121 pages

Satel Integra 64 User Manual - German - 54 pages

Satel Integra 64 Installation Guide - German - 38 pages

Satel Integra 64 Quick start guide - German - 2 pages

Satel Integra 64 User Manual - Dutch - 52 pages

Satel Integra 64 Quick start guide - Dutch - 24 pages

Satel Integra 64 Additional guide - Dutch - 121 pages

Satel Integra 64 Installation Guide - Dutch - 35 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info