SATEL INTEGRA Plus 19
No expanders tamper alarms allows to temporarily disable the expansion module
tamper supervision. In case of any problems with the expansion modules, report the fact
to the installer.
Permanent service access the option is available to the master user (administrator). If
enabled, the installer has permanent access to the alarm system, which, among other
things, enables the control panel to be programmed by using LCD keypad or DLOADX
program.
Enabling PERMANENT SERVICE ACCESS option will clear the installer access time
programmed with the SERVICE ACCESS function. On the other hand, programming the
installer access time will disable the PERMANENT SERVICE ACCESS option.
Service can edit the option is available to the master user (administrator). If it is
enabled, the installer can add, edit and delete users in the administrator's object.
Service arm/disarm/clear/bypass the option is available to the master user
(administrator). If it is enabled, the installer can arm/disarm the system, clear alarms
and bypass zones in the administrator object.
Permanent DLOADX access the option is available to the master user (administrator).
If it is enabled, the control panel can be programmed by means of the DLOADX
program, irrespective of whether or not the installer has access to the alarm system.
DLOADX IP enables programming the address of the computer, on which the DLOADX
program is installed. If the address is programmed, the control panel users can start
from the keypad the communication with the DLOADX program via ETHM-1 Plus /
ETHM-1 / INT-GSM module (see description of the ETHM-1 DLOADX and INT-GSM
DLOADX functions, available in the DOWNLOADING submenu). The address can be
entered as a name or IP address.
GUARDX IPenables programming the address of the computer, on which the GUARDX
program is installed. If the address is programmed, the control panel users can start
from the keypad the communication with the GUARDX program via ETHM-1 Plus /
ETHM-1 / INT-GSM module (see description of the ETHM-1 GUARDX and INT-GSM
GUARDX functions, available in the DOWNLOADING submenu). The address can be
entered as a name or IP address.
Erase service messageallows the user to delete the service message.
Teststhe following functions are available in the submenu:
Partitions allows to check the status of partitions accessible to the user and operated
from the keypad. The partition status is presented by means of a symbol. The numbers
placed on the glass allow you to identify the partition numbers. By factory default, the
partition status is shown using the following symbols (which can be changed by the
installer):
b - temporary partition blocking,
? - entry delay,
E - exit delay (less than 10 seconds),
e - exit delay (more than 10 seconds),
P - fire alarm,
A - alarm,
p - fire alarm memory,
a - alarm memory,
a - zone is armed,
- violated zones,
- zone is disarmed, zones OK.
21


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Satel Integra 256 Plus at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Satel Integra 256 Plus in the language / languages: English as an attachment in your email.

The manual is 1,4 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Satel Integra 256 Plus

Satel Integra 256 Plus Additional guide - English - 102 pages

Satel Integra 256 Plus Installation Guide - English - 35 pages

Satel Integra 256 Plus User Manual - German - 55 pages

Satel Integra 256 Plus Additional guide - German - 108 pages

Satel Integra 256 Plus Installation Guide - German - 36 pages

Satel Integra 256 Plus Quick start guide - Dutch - 2 pages

Satel Integra 256 Plus Additional guide - Dutch - 108 pages

Satel Integra 256 Plus User Manual - Dutch - 53 pages

Satel Integra 256 Plus Installation Guide - Dutch - 35 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info