699031
19
Zoom out
Zoom in
Previous page
1/51
Next page
SATEL INTEGRA Plus 17
Clear other alarms allows to silence the alarms from other objects, to which the user has
normally no access.
Abort voice messagingterminates the telephone messaging.
The messaging can be cancelled automatically together with alarm clearing. The
messaging cancellation rules are defined by the installer.
Armallows to arm the partitions accessible to the user from the given keypad.
Arm (2 codes)allows to initiate arming of the partitions which require entering 2 codes.
Disarm (2codes) allows to initiate disarming of the partitions which require entering 2
codes.
Defer auto-arming available when auto-arming delay countdown is running. It allows to
postpone by a programmed time period the auto-arming of the partition in which the auto-
arming delay countdown is running. Entering just zeros will block the auto-arming function
(until the next auto-arming time).
Set auto-arming delay available when the auto-arming delay is programmed for at least
one partition and the auto-arming delay countdown is not currently running in that partition.
It allows to postpone by a programmed time period the auto-arming of the partition.
Arming mode allows to select the arming mode which is to be used (the shortcut key is
shown in square brackets):
[0] full arming (to be used after everybody has left the protected area),
[1] full arming + bypasses (allows the users to stay in the protected area) the zones for
which the BYPASSED IF NO EXIT option is enabled by the installer will be bypassed,
[2] arming without interior (allows the users to stay in the protected area):
interior zones (3. INTERIOR DELAYED zone type) will be disarmed,
violating the exterior zone (8. EXTERIOR zone type) will trigger a silent alarm,
violating another alarm zone will trigger a loud alarm.
[3] arming without interior and without entry delay (allows the users to stay in the
protected area to be used when nobody else is to enter the protected area) this
arming mode is similar to the previous one, but the delayed zones operate as the
instant ones (no entry delay).
Cancel 1st code if the partition is armed/disarmed by means of two codes and the first
code has already been entered, the user can still cancel the consent to arming/disarming.
Change own codeallows the user to change his/her own code.
Change telephone code allows the user to change his/her own telephone code.
Change prefix available to the administrator, if the use of prefixes in the system has been
made available by the installer (the prefix length has been defined). It enables to program
the prefixes and the time to remind about the need to change the prefix. Each code will
have to be preceded by a prefix:
normal for everyday use. By default, it consists of a suitable number of digits 0 (e.g. if
the determined prefix length is 4, the default prefix is 0000),
DURESS for use, when the user has been forced to enter the code. Using the code will
trigger a silent alarm. By default, it consists of a suitable number of digits 4 (e.g. if the
determined prefix length is 3, the default prefix is 444).
Usersthe following functions are available in the submenu:
New userallows to create a new user (see: Adding new user” p. 27).
Edit userallows to edit the existing users (see: Edit user” p. 28).
Remove userallows to remove the existing users (see: Removing a user p. 28).
19


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Satel Integra 256 Plus at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Satel Integra 256 Plus in the language / languages: English as an attachment in your email.

The manual is 1,4 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Satel Integra 256 Plus

Satel Integra 256 Plus Additional guide - English - 102 pages

Satel Integra 256 Plus Installation Guide - English - 35 pages

Satel Integra 256 Plus User Manual - German - 55 pages

Satel Integra 256 Plus Additional guide - German - 108 pages

Satel Integra 256 Plus Installation Guide - German - 36 pages

Satel Integra 256 Plus Quick start guide - Dutch - 2 pages

Satel Integra 256 Plus Additional guide - Dutch - 108 pages

Satel Integra 256 Plus User Manual - Dutch - 53 pages

Satel Integra 256 Plus Installation Guide - Dutch - 35 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info