699031
57
Zoom out
Zoom in
Previous page
1/102
Next page
SATEL INTEGRA Plus 55
partition). If the option is disabled, zone violation will arm, and the zone restore will disarm
the partition.
CHIME in module with this option enabled, zone violation can be signaled in partition
keypads, code locks and readers expanders assigned to the same partition as the zone
(the option CHIME must be enabled in the expander).
No alarm sign. in keypadoption for 13. PANIC-SILENT zone type. If it is enabled, alarm from
this zone will not be signaled on keypads. Clearing this alarm by means of keypad will not
be possible.
Outputs signaling the silent panic alarm can be deactivated using the CLEAR LATCHED
OUTPUTS user function.
Video on disarmed if this option is enabled, violating the zone when the partition is
disarmed will activate the 15. VIDEO ON DISARMED type output.
Video on armedif this option is enabled, violating the zone when the partition is armed will
activate the 16. VIDEO ON ARMED type output.
Bypass disabledif this option is enabled, the user cannot bypass the zone.
Bypassed if no exit if this option is enabled, the zone will be automatically bypassed,
when no partition exit is registered during the partition exit delay countdown. The zone will
also be bypassed when the full + bypassesarming mode is on (registering a partition exit
is irrelevant then). The zone will be unbypassed after the partition is disarmed.
Alarm in arm state an option for the zone types 64-79. It is available, if the NO BYPASS IF
ARMED
option is enabled. When it is enabled, violating an armed zone will cause an alarm
(if the partition exit was registered upon arming).
Alarming option available for the 91. DETECTOR MASK zone type. If enabled, violation of the
zone will additionally trigger an alarm.
Auto-reset 3 with this option enabled, the zone can trigger up to 3 alarms. As long as the
alarm is not cleared or the partition is not armed/disarmed, violations of the zone will not
trigger any alarm.
Auto-reset 1 with this option enabled, the zone can trigger only 1 alarm. As long as the
alarm is not cleared or the partition is not armed/disarmed, violations of the zone will not
trigger any alarm.
Clearing Autoreset with this option enabled, alarm counters for the zones for which the
AUTO-RESET 3 or AUTO-RESET 1 option is enabled can be automatically reset at midnight
(violations of these zones will be able to trigger alarms again).
Pre-alarm if this option is enabled, alarms from the zone will be verified.
With verification an option for the zone types 0-2, 85-86 and 94-95. If it is enabled, alarms
from the zone will be verified.
Alarm from the zone with enabled PRE-ALARM or WITH VERIFICATION option will be an
unverified alarm, unless during verification (see description of the ALARM VERIFICATION
TIME parameter p. 46) an alarm will be caused by another zone with enabled PRE-
ALARM or WITH VERIFICATION option. In such a case, a verified alarm will be triggered.
Bell delay an option for the zone types 5 and 6. It changes the way of reaction to a zone
violation when armed. If the option is disabled, the alarm from zone will be delayed by
a programmed time period (ALARM DELAY). If the option is enabled, the zone will alarm
immediately (event, reporting and telephone messaging), but the loud signaling will be
delayed by a programmed time period (SIGNALING DELAY).
Delay in 2&3 type arming an option for the 3. INTERIOR DELAYED zone type. If the option is
enabled, the zone will be armed and act as a delayed one upon activation of the type 2
(without interior) and type 3 (without interior and without entry delay) arm mode.
57


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Satel Integra 256 Plus at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Satel Integra 256 Plus in the language / languages: English as an attachment in your email.

The manual is 1,13 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Satel Integra 256 Plus

Satel Integra 256 Plus User Manual - English - 51 pages

Satel Integra 256 Plus Installation Guide - English - 35 pages

Satel Integra 256 Plus User Manual - German - 55 pages

Satel Integra 256 Plus Additional guide - German - 108 pages

Satel Integra 256 Plus Installation Guide - German - 36 pages

Satel Integra 256 Plus Quick start guide - Dutch - 2 pages

Satel Integra 256 Plus Additional guide - Dutch - 108 pages

Satel Integra 256 Plus User Manual - Dutch - 53 pages

Satel Integra 256 Plus Installation Guide - Dutch - 35 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info