SATEL INTEGRA 71
Double call with this option enabled, the control panel must be called twice for the modem
communication to be established. The first time you must wait for the preprogrammed
number of rings and hang up. Then you must call back within three minutes and the
control panel will answer the call immediately. This solution makes it possible to connect
after the control panel some additional devices which will be activated after a preset
number of rings (e.g. answering machine, fax, etc.).
Pulse dialing 1/1.5 (off 1/2) this option applies to dialing the telephone numbers by using
the pulse mode. Before you enable it, make yourself familiar with the valid standard of
pulse dialing.
Rings before answer [Rings to answer] number of rings after which the control panel will
go off hook.
6.2 Printer options
Printing the option enables on-line events printout by the printer connected to the RS-232
port of control panel mainboard.
6.2.1 Printout options
Include reporting status [Monitor.status] on the printout will appear the information if the
particular event was sent to the monitoring station (printout of the event information will
take place not immediately but after transmission to the station has been completed).
Print names / descriptions [Names/descript] determines if, besides the numbers of zones,
outputs, modules and users, also their names and descriptions are to be printed.
Wide paperprintout width will be 132 columns (if the option is disabled: 80 columns).
2400 bps (off:1200 bps) data will be sent to RS-232 port at a rate of 2400 bps (if the
option is disabled - at a rate of 1200 bps).
CR+LF (off: CR) parameter determining the control mode of paper feed in the printer.
Use parity bit the parity check of data transferred from the control panel to the printer is
enabled.
Parity EVEN (off: ODD) option determines the mode of parity check of data transferred
from the control panel to the printer. The option is relevant only if the USE PARITY BIT option
is active.
The other parameters of RS-232 transmission are permanently programmed (8 data
bits, 1 stop bit).
All the parameters regarding transmission through RS-232 (i.e. transmission rate,
CR+LF, parity, data bits and stop bits) are to be set identically on the control panel and
on the connected printer. Otherwise the printer will not operate at all, or the printout
will be illegible.
6.2.2 Printout contents
The options define what kind of information will be contained in the printout.
6.3 Other options
Permitted simple access codes [Simple codes] with this option enabled, with this
option enabled, it is possible to use codes containing less than three different digits (e.g.
1111 or 1212) or consisting of consecutive digits (e.g. 3456).
Notify of necessity to change access code [Notify of code] with this option enabled, the
keypad will notify the user of the necessity to change access code, if it is known to other
users.
73


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Satel Integra 128 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Satel Integra 128 in the language / languages: English as an attachment in your email.

The manual is 1,32 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Satel Integra 128

Satel Integra 128 User Manual - English - 51 pages

Satel Integra 128 Installation Guide - English - 36 pages

Satel Integra 128 User Manual - German - 54 pages

Satel Integra 128 Additional guide - German - 121 pages

Satel Integra 128 Installation Guide - German - 38 pages

Satel Integra 128 Quick start guide - Dutch - 24 pages

Satel Integra 128 User Manual - Dutch - 52 pages

Satel Integra 128 Additional guide - Dutch - 121 pages

Satel Integra 128 Installation Guide - Dutch - 35 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info