699072
70
Zoom out
Zoom in
Previous page
1/102
Next page
68 Programming SATEL
displayed. Select the output to be tested and press the
or key. The keypad will display
a submenu which enables the output testing. By using the or key, you can
activate/deactivate the output. You can also deactivate the output by means of the numerical
keys. Press to quit the submenu and return to the list of system outputs.
The output under test will stop performing its previous function (if it was active, it will
be deactivated).
If there are wireless sirens in the system, starting the function of output testing will
unblock the signaling in them (the signaling is normally blocked for the service mode
duration). It should be remembered that the command to block/unblock the signaling is
sent out during polling. This will cause a delay whose duration depends on the
programmed response period.
When testing the control output for ASP-205 wireless siren, it should be remembered
that the signaling is only triggered during the polling.
6. System options
Most of the options and parameters described in this section can be programmed:
using the keypad, in the service mode, by means of the functions available in the OPTIONS
submenu,
using the DLOADX program, in the Optionswindow.
Shown in square brackets are the names used in keypads.
6.1 Telephone options
Reporting - TELEPHONE [Mon.TELEPHONE] with this option enabled, the control panel
can send event codes by means of the telephone line.
Reporting - GPRS [Mon.GPRS] if this option is enabled, the control panel can send event
codes via GPRS by using the SATEL GSM module.
The REPORTING GPRS option does not apply to GPRS reporting via the INT-GSM
module.
Reporting - ETHM [Mon.ETHM-1] the option is available if the ETHM-1 Plus / ETHM-1
module is connected to the control panel, but the INT-GSM module is not included in the
alarm system. If this option is enabled, the control panel can send event codes over
Ethernet by using the ETHM-1 Plus / ETHM-1 module.
Reporting ETHM/INT-GSM [Mon.ETHM-1] the option is available if the INT-GSM module
is installed in the alarm system. If this option is enabled, the control panel can send event
codes via Ethernet by using the ETHM-1 Plus / ETHM-1 module and/or via GPRS and
SMS by using the INT-GSM module.
Telephone messaging [Messaging] if this option is enabled, the control panel can send
notifications via the telephone network of the occurrence of specific events using voice or
text messages defined by the installer.
SMS messagingif this option is enabled, the control panel can send event notifications by
using SMS messages whose content is created automatically, based on the control panel
event log. The SATEL GSM module must be connected to the control panel.
If the INT-GSM module is installed in the alarm system, the SMS MESSAGING option is
not available. The SMS MESSAGING option does not apply to SMS messaging by the
INT-GSM module.
E-mail messaging [E-MAIL messag.] if this option is enabled, the control panel can send
event notifications by e-mail messages, the content of which is created automatically,
70


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Satel Integra 128 Plus at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Satel Integra 128 Plus in the language / languages: English as an attachment in your email.

The manual is 1,13 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Satel Integra 128 Plus

Satel Integra 128 Plus User Manual - English - 51 pages

Satel Integra 128 Plus Installation Guide - English - 35 pages

Satel Integra 128 Plus User Manual - German - 55 pages

Satel Integra 128 Plus Additional guide - German - 108 pages

Satel Integra 128 Plus Installation Guide - German - 36 pages

Satel Integra 128 Plus User Manual - Dutch - 53 pages

Satel Integra 128 Plus Additional guide - Dutch - 108 pages

Satel Integra 128 Plus Installation Guide - Dutch - 35 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info