54 Programming SATEL
80. ARMING violation of the zone will arm the partition to which the zone belongs.
Additionally, you can select a group of partitions which will also be armed (see: Groups of
partitions” p. 58).
81. DISARMING violation of the zone will disarm the partition to which the zone belongs.
Additionally, you can select a group of partitions which will also be disarmed (see: Groups
of partitions” p. 58).
82. ARM/DISARM the zone controls the arming status of the partition it belongs to.
The control mode depends on the CONTR. BY PULSE(OFF-BY STATE) option. Disarming may
simultaneously clear the alarm and cancel the messaging.
83. CLEARING ALARM violation of the zone will clear alarm in the selected group of partitions
(see: Groups of partitions p. 58) or the partition to which the zone belongs, and can also
cancel messaging.
84. GUARDviolation of the zone is recognized as recording the guard's round in the partition
to which the zone belongs.
85. ENTRY/EXIT CONDITIONAL similarly as the 0. ENTRY/EXIT type with an extra feature: the
zone becomes an instant one upon arming, if no partition exit is registered upon starting
the arming procedure.
86. ENTRY/EXIT FINALsimilarly as the 0. ENTRY/EXIT, but the zone restore during exit delay
countdown will terminate the exit delay countdown and arm the system.
87. EXIT FINAL similarly as the 6. EXIT, but the zone restore during exit delay countdown
will terminate the exit delay countdown and arm the system.
88. 24H BURGLARY a permanently armed zone. Its violation will cause the burglary alarm.
89. FINISHING EXIT DELAY zone violation will reduce the partition exit delay time. It is possible
to program a shorter exit delay time. If this value remains not programmed, the exit delay
will be reduced to 4 seconds from the zone violation. There will be no effect if the zone is
violated and the just running exit delay is shorter than that programmed for the zone.
90. DISABLING VERIFICATION zone violation will disable verification of alarms in the partition.
All alarms will be unverified until next arming.
91. DETECTOR MASK the permanently armed zone, dedicated to anti-masking control.
Violation of the zone will be treated by the control panel as detector trouble (masking).
92. OUTPUTS GROUP OFFthe zone allows to deactivate a selected group of outputs.
93. OUTPUTS GROUP ONthe zone allows to activate a selected group of outputs.
94. ENTRY/EXIT INTERIOR similarly as the 0. ENTRY/EXIT, but it will only be armed in the case
of full armed status (arming modes 0 and 1).
95. ENTRY INTERIOR similarly as the 1. ENTRY, but it will only be armed in the case of full
armed status (arming modes 0 and 1).
96. FIRE MONITORING permanently armed zone. After the zone is violated, fire alarm
information is saved to the control panel memory.
97. FIRE PANEL FAULT. MONIT. permanently armed zone. After the zone is violated, an event
is saved to the control panel memory.
4.3.6 Zone options
Power up delay when the option is enabled, the zone will be bypassed for 120 sec. after
power-up (which prevents triggering alarms e.g. when starting the alarm control panel).
Priority when this option is enabled, arming will be impossible, if the zone is violated (e.g.
windows have been left open, etc.).
Contr. by pulse(off-by state) option for 82. ARM/DISARM zone type. If it is enabled,
violation of the zone will arm/disarm the partition (depending on the current status of the
56


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Satel Integra 128 Plus at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Satel Integra 128 Plus in the language / languages: English as an attachment in your email.

The manual is 1,13 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Satel Integra 128 Plus

Satel Integra 128 Plus User Manual - English - 51 pages

Satel Integra 128 Plus Installation Guide - English - 35 pages

Satel Integra 128 Plus User Manual - German - 55 pages

Satel Integra 128 Plus Additional guide - German - 108 pages

Satel Integra 128 Plus Installation Guide - German - 36 pages

Satel Integra 128 Plus User Manual - Dutch - 53 pages

Satel Integra 128 Plus Additional guide - Dutch - 108 pages

Satel Integra 128 Plus Installation Guide - Dutch - 35 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info