699072
55
Zoom out
Zoom in
Previous page
1/102
Next page
SATEL INTEGRA Plus 53
34. 24H FIRE COMBUSTION
35. 24H FIRE WATER FLOW (FIRE)
36. 24H FIRE HEAT
37. 24H FIRE PULL STATION
38. 24H FIRE DUCT
39. 24H FIRE FLAME
The zone types from 32 to 39 cause a fire alarm. The names of zones and codes of events
from these zones are consistent with the Contact ID reporting format. The fire zones (except
for 24H FIRE BUTTON) can work with alarm verification.
40. 24H FIRE SUPERVISORY
41. 24H LOW WATER PRESSURE
42. 24H LOW CO2
43. 24H WATER VALVE DETECTOR
44. 24H LOW WATER LEVEL
45. 24H PUMP ACTIVATED
46. 24H PUMP FAILURE
47. NO ALARM ACTION may be used to control the outputs. Additional options (STORE TO
EVENT LOG
, NO REPORTING and STORE EVENT ONLY IF ARMED) enable the zone to be used for
other applications e.g. supervising the keybox.
48. 24H AUXILIARY PROTECTION LOOP
49. 24H AUXILIARY GAS DETECTOR
50. 24H AUXILIARY REFRIGERATION
51. 24H AUXILIARY LOSS OF HEAT
52. 24H AUXILIARY WATER LEAKAGE
53. 24H AUXILIARY FOIL BREAK
54. 24H AUXILIARY LOW BOTTLED GAS LEVEL
55. 24H AUXILIARY HIGH TEMPERATURE
56. 24H AUXILIARY LOW TEMPERATURE
57. TECHNICAL DOOR OPENzone intended for supervising the status of the door defined as
DEPENDENT DOOR in the module executing the access control functions (partition keypad,
code lock, readers expander).
58. TECHNICAL DOOR BUTTON zone violation will result in opening the door controlled by
the module executing the access control functions (partition keypad, code lock, readers
expander).
59. TECHNICAL AC LOSS intended for control of devices working together with the alarm
control panel e.g. additional power supply units. Violation of the zone will cause a trouble
condition.
60. TECHNICAL BATTERY LOW intended for control of the batteries of additional power
supply units working in conjunction with the control panel. Violation of the zone will cause
a trouble condition.
61. TECHNICAL GSM LINK TROUBLE intended for control of the external GSM
communication module. Violation of the zone will cause a trouble condition.
62. TECHNICAL OVERLOAD intended for control of an additional power supply unit used
together with the control unit. Violation of the zone will cause a trouble condition.
63. TROUBLEviolation of the zone will cause a trouble condition.
64...79 BYPASSING GROUP: 1–16violation of this type of zone can bypass a group
of zones (see: Bypasses” p. 57).
55


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Satel Integra 128 Plus at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Satel Integra 128 Plus in the language / languages: English as an attachment in your email.

The manual is 1,13 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Satel Integra 128 Plus

Satel Integra 128 Plus User Manual - English - 51 pages

Satel Integra 128 Plus Installation Guide - English - 35 pages

Satel Integra 128 Plus User Manual - German - 55 pages

Satel Integra 128 Plus Additional guide - German - 108 pages

Satel Integra 128 Plus Installation Guide - German - 36 pages

Satel Integra 128 Plus User Manual - Dutch - 53 pages

Satel Integra 128 Plus Additional guide - Dutch - 108 pages

Satel Integra 128 Plus Installation Guide - Dutch - 35 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info