Fig. 3. Connection of the keypad to the control panel.
10. Connect the supply wires to the KPD and COM terminals. The keypad can be powered
directly from the control panel, from expander with power supply or from a power supply
unit. The table below shows requirements regarding the power wires (KPD and COM), if
conductors with 0.5 mm diameter are used.
Distance from control panel Number of parallel connected wires
up to 25 m 1
25 – 50 m 2
50 – 75 m 3
75 – 100 m 4
If the keypad is to be powered directly from the control panel, the keypad KPD
terminal:
INTEGRA 64 / INTEGRA 128 / INTEGRA 64 Plus / INTEGRA 128 Plus /
INTEGRA 256 Plus: can be connected to the +KPD terminal of the control panel,
INTEGRA 24 / INTEGRA 32 / INTEGRA 128-WRL: should be connected to the
OUT1 or OUT2 terminal of the control panel (only high-current outputs have
a sufficient current rating – program the output type as 41. POWER SUPPLY),
VERSA 5 / VERSA 10 / VERSA 15 / VERSA Plus / VERSA IP: should be connected
to the “+” terminal of OUT1 or OUT2 high-current output of the control panel (only
high-current outputs have a sufficient current rating).
11. Place the front panel onto the catches, snap close the enclosure.
3.1 Description of terminals
KPD - power supply input.
COM - common ground.
DTM - data.
CKM - clock.
Z1, Z2 - zones.
RSA, RSB - terminals provided for future applications (RS-485).
6


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Satel INT-TSH-BSB at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Satel INT-TSH-BSB in the language / languages: English as an attachment in your email.

The manual is 1,29 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Satel INT-TSH-BSB

Satel INT-TSH-BSB User Manual - English - 20 pages

Satel INT-TSH-BSB Quick start guide - English - 2 pages

Satel INT-TSH-BSB User Manual - English - 19 pages

Satel INT-TSH-BSB Quick start guide - Dutch - 2 pages

Satel INT-TSH-BSB Installation Guide - Dutch - 20 pages

Satel INT-TSH-BSB Installation Guide - Dutch - 28 pages

Satel INT-TSH-BSB User Manual - Dutch - 19 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info