12 INT-TSG SATEL
7 – trouble status [Troubles] – if this option is enabled, you can view the current troubles
without entering the code:
– after tapping on the “System status” screen,
after tapping and holding for 3 seconds on the terminal.
8 – chime on/off [Chime changing] – if this option is enabled, the user can switch on/off the
CHIME signal in the keypad by means of the terminal, tapping and holding for about 3
seconds on the terminal.
Zone state [Zone characters] – you can define the symbols which will be used by the
terminal to illustrate the state of zones.
Partition state [Part. characters] – you can define the symbols which will be used by the
terminal to illustrate the state of partitions.
7.1.3 User functions definition
Code+arrows – you can define which functions will be started on entering the code and
tapping the selected arrow key.
7.1.4 Macro commands
The macro commands related data are stored in the keypad memory. Before you start
defining the macro commands, click on the “Read” button in the “Macro commands”
tab to read the data from the keypad. Having defined the macro commands, click on
the “Write” button in the “Macro commands” tab to write the data to the keypad. The
macro command related data are not read / written when you click on the button
in the main menu of D
LOAD
X program.
In the keypad with factory default settings, there are two macro commands defined
which are assigned to the first group:
0# – quick full arming (the control panel will only execute the macro command after
you define the partitions which are to be armed in the event of quick full arming –
see Q
UICK
A
RM PARTITIONS
p. 7);
9# – exit delay clearing (the control panel will execute the macro command if reducing
the exit delay time is allowed by the partition settings and the E
XIT DELAY CLEARING
ENABLE
option is enabled in the keypad – see p. 9).
The “Reset” button in the D
LOAD
X program makes it possible to restore the keypad
factory settings, i.e. those related to macro commands, status screen and EOL
resistors (in the case of the keypads supported by the INTEGRA Plus control panels,
the EOL resistor values are not programmed individually for keypad zones).
Groups
The macro commands which are to be available for the keypad users must be assigned to
one of the four groups. Up to 16 macro commands can be assigned to a group. Up to 6
macro command icons can be displayed on the keypad screen at the same time. The
D
LOAD
X program presents groups of macro commands and macro commands assigned to
them in a tree form.
Name – name of the macro command group which is displayed on the keypad screen under
the icon (up to 16 characters in two lines, up to 8 characters in the line). Do not enter the
name if it is not to be displayed.
14


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Satel INT-TSG-BSB at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Satel INT-TSG-BSB in the language / languages: English as an attachment in your email.

The manual is 0,8 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Satel INT-TSG-BSB

Satel INT-TSG-BSB Quick start guide - English - 2 pages

Satel INT-TSG-BSB User Manual - English - 20 pages

Satel INT-TSG-BSB User Manual - English - 18 pages

Satel INT-TSG-BSB Quick start guide - German - 2 pages

Satel INT-TSG-BSB User Manual - German - 19 pages

Satel INT-TSG-BSB Installation Guide - German - 29 pages

Satel INT-TSG-BSB Quick start guide - Dutch - 2 pages

Satel INT-TSG-BSB User Manual - Dutch - 18 pages

Satel INT-TSG-BSB User Manual - Dutch - 20 pages

Satel INT-TSG-BSB Installation Guide - Dutch - 28 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info