3. CONTROL PANEL CHARACTERISTICS
3.1 Z
ONES
The CA-5 control panel has 5 zones, all of them on the mainboard. The control panel
accepts any detectors connected in the NC, NO, EOL, 2EOL/NC, and 2EOL/NO
configuration. The 2EOL configuration allows the control panel to simultaneously control the
detector and its tamper circuit while using one pair of wires.
The zones can serve the following functions in the system:
0 –
ENTRY
/
EXIT
(monitors entry to and exit from the facility by the user; having detected
entry into the facility, it actuates the mechanism of interior zone alarm delay)
1 –
INTERIOR DELAY
(if there is no entry into the facility, it works as the instant zone)
2 –
INSTANT
(triggers alarm instantly after violation when the control panel is armed)
3 –
COUNTING
(to 2 violations throughout the monitoring time as determined by the entry
delay – the second violation will trigger alarm)
4 – 24
H PANIC
(armed 24 hours; makes it possible to connect panic buttons)
5 – 24
H FIRE
(armed 24 hours; triggers the fire alarm)
6 – 24
H TAMPER
(armed 24 hours)
7 –
ARMING
/
DISARMING
,
ALARM CLEARING
(makes it possible to connect remote control set)
8 –
PERIMETER
(armed from starting the exit delay countdown)
9 –
ENTRY
/
EXIT FINAL
(having detected the end of violation of this zone, the alarm control
panel will end the exit delay countdown and enter the armed mode)
10 –
DELAYED
The number of zone function corresponds to the number programmable in the FS 26–30
service functions to determine the type of zone reaction.
The reaction time for each zone can be programmed from 0.016 s to 4.08 s (FS 16–20).
For the zones types 0, 1, 3, 9 and 10, individual delay times can be set (FS 31–35).
For each zones, it is possible to determine six codes of events to be sent to the monitoring
stations (FS 57, FS 58, FS 60, FS 61, FS 80 and FS 81).
The zones can be selectively bypassed with the user function 4, while bypassing of the 24h
zones is only possible by using the service code.
See also: S
ETTINGS LIST
, section „Zones”.
3.2 O
UTPUTS
The CA-5 is fitted with 3 signal outputs (OUT1, OUT2, OUT3) and 2 power supply outputs
(AUX and KPD).
The OUT1 output (high-current, 1.1 A polymer fuse) is a specialized alarm output. It is
intended for connecting an audible siren. This output has two terminals: +OUT1 and –OUT1.
Activation of the output is effected by shorting the -OUT1 terminal to the common (basic
output polarization).
The +OUT1 terminal serves the function of a power supply output with 1.1 A polymer fuse.
The control panel monitors the fuse condition and signals output overload.
The OUT1 output can be assigned to selected control panel zone (FS 41 – 45). The selection
applies also to other
BURGLARY ALARM
outputs.
The low-current OUT2 and OUT3 outputs (OC, up to 50 mA) are programmable and each
of them can serve one of the following functions:
0 –
NOT USED
5


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Satel CA-5 Plus at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Satel CA-5 Plus in the language / languages: English as an attachment in your email.

The manual is 0,5 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Satel CA-5 Plus

Satel CA-5 Plus Additional guide - English - 20 pages

Satel CA-5 Plus User Manual - English - 24 pages

Satel CA-5 Plus User Manual - German - 24 pages

Satel CA-5 Plus Additional guide - German - 20 pages

Satel CA-5 Plus User Manual - German - 24 pages

Satel CA-5 Plus Installation Guide - German - 28 pages

Satel CA-5 Plus User Manual - Dutch - 24 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info