CA-10 SATEL
3
answering phone calls and informing the user of the system status (whether there
was an alarm condition since last arming),
MONITORING - communication with telephone monitoring stations (real-time
transmission of detailed information about selected events in the protected facility),
printing current information about all the system events on an external printer.
Features of CA-10:
panel operation controlled with remote keypads,
remote control by means of a telephone set (selected functions) - interfacing with
the MST-1 module,
real-time status display for armed zones,
viewing alarm condition and trouble logs available (for up to 255 events),
option to subdivide the alarm system into 4 partitions (subsystems),
any partition can be operated by up to 13 users with independent access codes
(up to 32 access codes) - the access codes can have different authority level, any
instance of using them is recorded in the event log,
remote control of locks, lighting system and other devices from the panel keypads,
activation of PANIC, FIRE and AUXILIARY alarms from the keypads,
various system arming options (with automatic bypassing, with no-exit bypassing),
internal clock capable of automatic arming and disarming of the system,
automatic diagnostics of the basic components of the alarm system.
Armed Modes
To adapt the alarm system to various needs, the CA-10 control panel offers several
armed modes:
Full armed mode
The mode in which detectors connected to the panel control the protected facility and
violation of the protected zones is signaled by the panel with all available means (sirens,
reporting to telephone monitoring stations, telephone messages).
Silent armed mode
Armed mode in which alarms are signaled only in the panel keypads. The installer can
decide which of the detectors are to be automatically bypassed on activating this mode;
he can also choose signaling device to be used in that mode.
Partially armed mode
The installer can determine the detectors in the system which will be excluded from the
supervision when the system is armed with a special access code (authority level 7).
The user can, by entering an appropriate code, arm the system in a chosen part of the
facility only.
Stay armed mode
In this mode the panel enables automatic bypassing of chosen detectors if after arming
the user did not leave the supervised area and did not violate the entry/exit zone.
5


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Satel CA-10 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Satel CA-10 in the language / languages: English as an attachment in your email.

The manual is 0,33 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Satel CA-10

Satel CA-10 User Manual - English - 2 pages

Satel CA-10 User Manual - English - 2 pages

Satel CA-10 User Manual - English - 2 pages

Satel CA-10 Additional guide - English - 60 pages

Satel CA-10 Additional guide - English - 24 pages

Satel CA-10 Quick start guide - English - 11 pages

Satel CA-10 Installation Guide - English - 43 pages

Satel CA-10 User Manual - German - 2 pages

Satel CA-10 User Manual - German - 4 pages

Satel CA-10 Additional guide - German - 64 pages

Satel CA-10 Additional guide - German - 24 pages

Satel CA-10 User Manual - German - 26 pages

Satel CA-10 Installation Guide - German - 44 pages

Satel CA-10 User Manual - Dutch - 2 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info