6. Cleaning and care of the unit
The unit should be cleaned occasionally.
Important
To avoid odours caused by fluff and dust, we recommend regularly cleaning the device as follows:
The device must be switched off and allowed to cool and the mains plug pulled out before cleaning and
changing the infrared heat lamp.
Ensure that no water penetrates inside the unit!
Do not wash the unit in a washing machine!
Clean using a damp cloth, to which you can apply a little detergent if necessary.
Do not touch the unit with wet hands while it is plugged in; do not allow any water to be sprayed onto the
unit. The unit must be operated only when it is completely dry.
Do not use abrasive detergents and never immerse the unit in water.
7. Disposal
In the interest of protecting the environment, the unit must not be thrown out with the household waste at the
end of its service life. Dispose of the unit at a suitable local collection or recycling point.
Please dispose of the device in accordance with EC Directive – WEEE (Waste Electrical and Electronic
Equipment).
If you have any queries, please contact the appropriate local authorities.
8. Technical specifications
Mains connection SIL 06: 220-230 V~ / 50-60 Hz; SIL 16: 220-230 V~ / 50-60 Hz
Power consumption SIL 06: 100 W; SIL 16: 150 W
Max. Radiation intensity 1900 W/m
2
at 380-3000 nm
Dimensions (W x H x D) SIL 06: 120 x 205 x 165 mm
SIL 16: 145 x 220 x 175 mm
Weight SIL 06: approx. 320g / SIL 16: approx. 600g
Operating conditions Temperature: +5°C to +35°C; Relative humidity: 15%-93%
Storage and transport Temperature: -25°C to +70°C; Relative humidity: ≤93%
Expected operating life of the device 7 years
Subject to technical modifications. This device meets the requirements of the European Medical Devices Direc
-
tive 93/42/EEC with amendments as well as the German Medical Devices Act.
Subject to errors and changes
10


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Sanitas SIL 06 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Sanitas SIL 06 in the language / languages: English, German, French, Italian as an attachment in your email.

The manual is 2,22 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info