In the initial minutes, carry out the application sitting or lying down in order
to avoid any unnecessary risk of injury in the rare event of a vagal reac-
tion (feeling of weakness). If you start feeling weak, switch the machine off
immediately and put your legs up (approx. 5–10 minutes).
It is not advisable to apply any enriching creams or ointments to the skin be-
forehand, as this greatly increases electrode wear or else unpleasant current
spikes may occur here.
Damage
If the device is damaged, do not use it and contact your retailer or the speci-
fied Customer Services address.
Check the device at regular intervals for signs of wear or damage. If you find
any such signs or if the device was used improperly, you must bring it to the
manufacturer or dealer before it is used again.
Switch off the device immediately if it is defective or if is not working properly.
Do not, under any circumstances, attempt to open or repair the machine your-
self! Only have repairs carried out by the customer service department or an
authorized dealer. If these instructions are not heeded, the warranty becomes
null and void.
The manufacturer assumes no liability for damage caused through improper or
wrong use.
3. Current parameters
Electrical stimulation machines operate with the following current settings,
which will alter the stimulation effect depending on the setting.
3.1 Pulse shape
This describes the time function of the excitation current
whereby monophase pulse trains are differentiated from
biphase. With monophase pulse trains, the current flows in
one direction. With biphase pulses, the excitation current
alternates its direction.
In the Digital EMS/TENS unit, there are only biphase pulse
trains, as they reduce the strain on the muscle, leading to
less muscle fatigue as well as safer application.
3.2 Pulse frequency
Frequency indicates the number of individual pulses per
second, and is indicated in Hz (Hertz). It can be calculated
by working out the inverse value of the periodic time. The
respective frequency determines which types of muscle fibre preferably react.
Slow-response fibres tend to react to lower pulse frequencies up to 15 Hz, while
fast-response fibres only respond to frequencies over approx. 35 Hz.
With pulses of approx. 45–70 Hz, there is permanent tension in the muscle com-
bined with premature muscle fatigue. Higher pulse frequencies can therefore
preferably be used for elasticity and maximum strength training.
3.3 Pulse width
Pulse width is used to indicate the duration of an individual
pulse in microseconds. Pulse width also determines the
pene tration depth of the current whereby in general, the fol-
lowing applies: a greater muscle mass requires a greater
pulse width.
3.4 Pulse intensity
Setting the degree of intensity is individually depend-
ent on the subjective feeling of each individual user and is
determined by a number of parameters such as application
site, skin circulation, skin thickness as well as quality of
electrode contact. The actual setting should be effective but should never pro-
duce any unpleasant sensations such as pain at the site of application. While
a slight tingling sensation indicates sufficient stimulation energy, any setting
which leads to pain must be avoided.
With prolonged application, readjustment may be necessary due to time adjust-
ment processes at the site of application.
3.5 Cycle-controlled pulse parameter variation
In many cases it is necessary to cover the entirety of tissue structures at the site
of application by using several pulse parameters. With the Digital EMS/TENS
unit, this is done by the existing programmes automatically making a cyclical
pulse parameter change. This also prevents individual muscle groups at the site
of application from getting tired.
With the Digital EMS/TENS unit there are useful presettings for current para-
meters. With this, you can change the impulse intensity at any time during use.
For 6 programs you can also set various parameters for stimulation yourself.
pulse
intensity
monophase pulses
time
biphase pulses
periodic
time
Pulse width
19


Need help? Post your question in this forum.

Forumrules
1

Forum

sanitas-sem-43

Reset search

  • can I stick the electrodes high on my back? between the shoulder blades? or is this dangerous because it's too close to the heart? Submitted on 28-2-2020 at 09:10

    Reply Report abuse


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Sanitas SEM 43 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Sanitas SEM 43 in the language / languages: English, German, French, Italian as an attachment in your email.

The manual is 2,83 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info