Guidance and manufacture’s declaration – electromagnetic immunity
a
Field strengths from fi xed transmitters, such as base stations for radio (cellular/cordless) telephones and land mobile
radios, amateur radio, AM and FM radio broadcast and TV broadcast cannot be predicted theoretically with accuracy.
To assess the electromagnetic environment due to fi xed RF transmitters, an electromagnetic site survey should be con-
sidered. If the measured fi eld strength in the location in which the SBM52 blood pressure monitor is used exceeds the
applicable RF compliance level above, the SBM52 blood pressure monitor should be observed to verify normal opera-
tion. If abnormal performance is observed, additional measures may be necessary, such as reorienting or relocating the
SBM52 blood pressure monitor.
b
Over the frequency range 150 kHz to 80 MHz, fi eld strengths should be less than 3 V/m.
Recommended separation distances between portable and mobile RF communications equipment and the
EQUIPMENT or SYSTEM – for EQUIPMENT or SYSTEM that are not LIFE-SUPPORTING
Recommended separation distances between portable and mobile RF communications equipment and the SBM52
blood pressure monitor
The SBM52 blood pressure monitor is intended for use in an electromagnetic environment in which radiated RF distur-
bances are controlled. The customer or the user of the SBM52 blood pressure monitor can help prevent electroma-
gnetic interference by maintaining a minimum distance between portable and mobile RF communications equipment
(transmitters) and the SBM52 blood pressure monitor as recommended below, according to the maximum output
power of the communications equipment.
Rated maximum output
power of transmitter
(W)
Separation distance according to frequency of transmitter
(m)
150 kHz to 80 MHz
d =
80 MHz to 800 MHz
d =
800 MHz to 2.5 GHz
d =
0.01 0.117 0.117 0.234
0.1 0.370 0.370 0.740
11.1701.1702.340
10 3.700 3.700 7.400
100 11.7 11.7 23.4
For transmitters rated at a maximum output power not listed above, the recommended separation distance d in
metres (m) can be estimated using the equation applicable to the frequency of the transmitter, where P is the maxi-
mum output power rating of the transmitter in watts (W) according to the transmitter manufacturer.
NOTE 1 At 80 MHz and 800 MHz, the separation distance for the higher frequency range applies.
NOTE 2 These guidelines may not apply in all situations. Electromagnetic propagation is a ected by absorption and
refl ection from structures, objects and people.
32


Need help? Post your question in this forum.

Forumrules
1

Forum

sanitas-sbm-52

Reset search

  • KODEL sanitas sbm 52 NEKALBA NEPASAKO NEI LAIKO NEI Datos bei parodymu

    Submitted on 11-1-2023 at 00:42

    Reply Report abuse
  • Os meus aparelhos S B M 52 da sanitas não estão calibrados e dão muitas vezes erro. Onde poderei pedir assistência. Resido em Coimbra. Cumprimentos.
    Submitted on 16-3-2022 at 13:21

    Reply Report abuse
  • Since I changed the batteries on my SMB52 the language has changed to Italian how can I change back to english Submitted on 22-7-2018 at 12:09

    Reply Report abuse


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Sanitas SBM 52 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Sanitas SBM 52 in the language / languages: English, Portuguese as an attachment in your email.

The manual is 4,21 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Sanitas SBM 52

Sanitas SBM 52 User Manual - German - 16 pages

Sanitas SBM 52 User Manual - Dutch, French - 32 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info