Electromagnetic Compatibility Information
Guidance and manufacture’s declaration – electromagnetic emissions – for all EQUIPMENT and SYSTEMS
Guidance and manufacture’s declaration – electromagnetic emission
The SBM52 blood pressure monitor is intended for use in the electromagnetic environment specifi ed below. The custo-
mer of the user of the SBM52 blood pressure monitor should assure that it is used in such and environment.
Emission test
Compliance
Electromagnetic environment – guidance
RF emissions CISPR 11 Group 1 The SBM52 blood pressure monitor uses RF energy only for its internal function.
Therefore, its RF emissions are very low and are not likely to cause any interfe-
rence in nearby electronic equipment.
RF emission CISPR 11 Class B
The SBM52 blood pressure monitor is suitable for use in all establishments, inclu-
ding domestic establishments and those directly connected to the public low-vol-
tage power supply network that supplies buildings used for domestic purposes.
Guidance and manufacture’s declaration – electromagnetic immunity – for all EQUIPMENT and SYSTEMS
Guidance and manufacture’s declaration – electromagnetic immunity
The SBM52 blood pressure monitor is intended for use in the electromagnetic environment specifi ed below. The custo-
mer or the user of the SBM52 blood pressure monitor should assure that it is used in such an environment.
Immunity test IEC 60601
test level
Compliance
level
Electromagnetic environment – guidance
Electrostatic discharge (ESD)
IEC 61000-4-2
± 6 kV contact
± 8 kV air
± 6 kV contact
± 8 kV air
Floors should be wood, concrete or ceramic tile. If oor
are covered with synthetic material, the relative humi-
dity should be at least 30%.
Power frequency (50Hz)
magnetic fi eld
IEC 61000-4-8
3 A/m 3 A/m
Power frequency magnetic elds should be at levels
characteristic of a typical location in a typical commer-
cial or hospital environment.
Guidance and manufacture’s declaration – electromagnetic immunity – for EQUIPMENT and SYSTEMS that are not
LIFE-SUPPORTING
Guidance and manufacture’s declaration – electromagnetic immunity
The SBM52 blood pressure monitor is intended for use in the electromagnetic environment specifi ed below. The custo-
mer or the user of the SBM52 blood pressure monitor should assure that it is used in such an environment.
Immunity test IEC 60601
test level
Compliance
level
Electromagnetic environment – guidance
Conducted RF
IEC 61000-4-6
Radiated RF
IEC 61000-4-3
3 V
rms
150 kHz to
80 MHz
3 V/m
80 MHz to
2.5 GHz
3 V
rms
3 V/m
Portable and mobile RF communications equipment should be used no clo-
ser to any part of the SBM52 blood pressure monitor, including cables, than
the recommended separation distance calculated from the equation appli-
cable to the frequency of the transmitter.
Recommended separation distance:
d =
d = 80 MHz to 800 MHz
d =
800 MHz to 2.5 GHz
Where P is the maximum output power rating of the transmitter in watts (W)
according to the transmitter manufacturer and d is the recommended sepa-
ration distance in metres (m).
Field strengths from fi xed RF transmitters, as determined by an electroma-
gnetic site survey,
a
should be less than the compliance level in each fre-
quency range.
b
Interference may occur in the vicinity of
equipment marked with the following symbol:
NOTE 1 At 80 MHz and 800 MHz, the higher frequency range applies.
NOTE 2 These guidelines may not apply in all situations. Electromagnetic propagation is a ected by absorption and
refl ection from structures, objects and people.
31


Need help? Post your question in this forum.

Forumrules
1

Forum

sanitas-sbm-52

Reset search

  • KODEL sanitas sbm 52 NEKALBA NEPASAKO NEI LAIKO NEI Datos bei parodymu

    Submitted on 11-1-2023 at 00:42

    Reply Report abuse
  • Os meus aparelhos S B M 52 da sanitas não estão calibrados e dão muitas vezes erro. Onde poderei pedir assistência. Resido em Coimbra. Cumprimentos.
    Submitted on 16-3-2022 at 13:21

    Reply Report abuse
  • Since I changed the batteries on my SMB52 the language has changed to Italian how can I change back to english Submitted on 22-7-2018 at 12:09

    Reply Report abuse


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Sanitas SBM 52 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Sanitas SBM 52 in the language / languages: English, Portuguese as an attachment in your email.

The manual is 4,21 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Sanitas SBM 52

Sanitas SBM 52 User Manual - German - 16 pages

Sanitas SBM 52 User Manual - Dutch, French - 32 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info