6. Saving, retrieving and deleting results
The results of each successful measurement are stored to-
gether with date and time. With more than 60 items of meas-
ured data, the earliest items of data measured are lost.
Select the desired user memory by pressing the MEM but-
ton and then the “+” button. Press the MEM button again to
display the average of all saved measurements in the user
memory. Press the MEM button again to display the average
day measurement for the last 7 days. (day: 5.00 a.m. – 9.00
a.m., display A). Press the MEM button again to display the
average night measurement for the last 7 days
(night: 5.00 p.m. – 9.00 p.m., display P). If you continue press-
ing the MEM button, the latest individual results are displayed
with date and time.
To clear the memory, press the MEM button, then the display
shows no. 1. Press the “+” button to select the user memory
and confirm by pressing MEM again. Press and hold the “+”
and keys simultaneously for 5 seconds (the display will
show CLA).
If you wish to change the user memory, see “Select memory”.
7. Error messages / troubleshooting
In case of faults, the E_ message appears in the display.
Error messages can occur when
1. inflation pressure is higher than 300 mmHg E2.
2. blood pressure is unusually high or low E3.
3. you move or talk during the measurement (in addition to E_,
the cardiac arrhythmia icon appears in the display E3),
4. the cuff tube is not inserted properly E1.
5. the cuff is inflated for longer than 25 seconds E1.
In the above cases, you must repeat the measurement. Make
sure that the cuff tube is properly inserted and that you do
not move or talk. Re-insert the batteries if necessary, or else
replace them.
8. Cleaning and Care
Clean your blood pressure computer carefully using only a
slightly moistened cloth.
Do not use any detergents or solvents.
Never hold the instrument under water as otherwise liquid
can penetrate and damage the instrument.
Never place any heavy objects on the instrument.
9. Technical details
Model no. SBC 27
Measurement Oscillating, non-invasive blood
method pressure measurement on the wrist
Measurement range systolic 40 – 280 mmHg,
diastolic 40 – 280 mmHg,
pulse 40 –199 beats / minute
Precision of Systolic ±
3 mmHg
/
pressure reading diastolic ±
3 mmHg
/
pulse ±
5
% of displayed value
Measurement Max. admissible standard deviation
uncertainty according to clinical examination.
systolic 8 mmHg
/
diastolic 8 mmHg
Memory 2 x 60 storable data lines
Dimensions L 72 x W 69 x H 29,2 mm
Weight Approx. 115 g
Cuff size For a wrist circumference of approx.
135 to 195 mm
15


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Sanitas SBC 27 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Sanitas SBC 27 in the language / languages: English, German, French, Italian as an attachment in your email.

The manual is 1,16 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info