684544
29
Zoom out
Zoom in
Previous page
1/46
Next page
28
English
Installation
Step 1.1 Choosing the installation
location
Overview of installation location requirements
100 mm or more
Outdoor
Unit
Indoor
Unit
Cut insulation to have
rainwater drained
Outer wall
Drain hose hole
You can select the direction of
draining (left or right).
Maximum pipe height: 15 m
Maximum pipe length: 30 m
125 mm
or more
125 mm
or more
The actual units may look different from
the images depicted here.
Make a U-trap (A) on the
pipe (which is connected to
the indoor unit) at outer wall
and cut the bottom part of
the insulation (about 10 mm)
to prevent rainwater from
getting inside through the
insulation.
Make at least one round to
reduce noise and vibration.
CAUTION
CAUTION
Comply with the length and height limits described
in the figure above.
Minimum clearances for the outdoor unit
Wall
Minimum clearance in mm
300
600
Air flow direction
Side viewTop view
When installing 1 outdoor unit (6 cases)
(Unit: mm)
300
1500
1500
2000
500
300
300 1500
(Unit : m)
Model
Pipe length Pipe height
Minimum Maximum Maximum
✴✴09/12/18✴✴ 3 15 7
✴✴24✴✴ 3 20 8
Preparation
DB68-06031A-01_A5.indd 28 4/18/2017 8:59:36 AM
29


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Samsung AR12KPFNDWK at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Samsung AR12KPFNDWK in the language / languages: English as an attachment in your email.

The manual is 21,83 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info