Installation
Step 4.3 Performing final check and trial
operation
1. Check the following:
Strength of the installation site
Tightness of pipe connection to detect gas
leak
Electric wiring connection
Heat-resistant insulation of the pipe
Drainage
Grounding conductor connection
Correct operation (Take the following steps.)
2. Press the
(Power) button on the remote
control to check the following:
The indicator on the indoor unit lights up.
The airflow blade opens and the fan gears up
for operation.
3. Press the
(Mode) button to select Cool or Heat
mode. Then take the following sub-steps:
In Cool mode, use the Temperature button to
set the set temperature to 16 °C.
In Heat mode, use the Temperature button to
set the set temperature to 30 °C.
Check whether, approximately 3 to 5 minutes
later, the outdoor unit starts, and a cool or
warm air blows out.
After 12 minutes of stationary condition, check
the indoor unit air treatment.
4. Press the
(Air swing) button to check whether
the airflow blades work properly.
5. Press the
(Power) button to stop the trial
operation.
Pumping down refrigerant
Pump-down is an operation intended to collect
all the system refrigerant in the outdoor unit. This
operation must be carried out before disconnecting the
refrigerant tubing in order to avoid refrigerant loss to the
atmosphere.
1. Shut off the liquid valve with the Allen wrench.
2. Turn on the air conditioner in cooling with fan
operating at high velocity. (Compressor will
immediately start, provided 3 minutes have
elapsed since the last stop.)
3. After 2 minutes of operation, shut the suction
valve with the same wrench.
4. Turn off the air conditioner and switch mains
supply off.
5. Disconnect tubing. After disconnection, protect
valves and tubing ends from dust.
CAUTION
Compressor damage may occur if the compressor is
run at a negative suction pressure.
Pumping down for removing the product
1. Turn on th air conditioner and select Fast Cool
mode.
2. Let the compressor run for more than 5 minutes.
If the compressor does not operate for more than
5 minutes due to protection control, wait about 2
minutes, and then carry out the next procedure.
3. Release the valve caps on High and Low pressure
side.
4. Use L-wrench to close the valve on the high
pressure side.
5. After approximately 1 minute, close the valve on
the low pressure side.
6. Stop operation of the air conditioner by pressing
the
(Power) button on the indoor unit or
remote control.
7. Disconnect the pipes.
1
2
Gas service port
<Low pressure>
Liquid service port
<High pressure>
1 minute
Off
DB68-06031A-01_A5.indd 45 4/18/2017 9:00:06 AM
46


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Samsung AR12KPFNDWK at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Samsung AR12KPFNDWK in the language / languages: English as an attachment in your email.

The manual is 21,83 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info