6.2 Combustion air
The required oxygen for the fire is supplied through inlet below the door of the appliance.
An optimal combustion requires sufficient fresh air (see technical data). A lack of oxygen may result in
incomplete combustion and reversing flue gases.
Additional combustion air can be supplied by placing an air inlet grill as close as possible to the appliance. Air
inlet grills must be positioned so that they are not liable to blockage.
Combustion air can also be supplied from the outside. To do so, a steel pipe must be connected to the
external air adaptor (optional). This is performed as follows:
Rear connection
1. Remove the pre-cut cover on the rear of the convection
mantle.
2. Link the connector with the pipe for the combustion air
using a tie down strap. Then secure the connection on the
rear of the combustion chamber with 3 screws.
3. Place the cover plate around the pipe and screw it tight.
Bottom connection
1. Remove the pre-cut cover at the bottom of the mantle.
2. Secure the connector on the rear of the combustion
chamber using the 3 screws included
3. Place the connection in the connector and secure the
connection on the convection mantle using the 2 remaining
screws.
The combustion air connection at the bottom requires a height
under the convection mantle of 120mm and a depth behind the
convection mantle of around 50mm.
ATTENTION!
Extractor fans when operating in the same room or space as the appliance may cause problems.
48


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Saey High Line 80 S at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Saey High Line 80 S in the language / languages: English, Dutch, French as an attachment in your email.

The manual is 2.39 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info