Thermal insulation is required if adjacent construction elements must be protected against high temperatures
(e.g. inflammable materials or load-bearing walls). Insulation wool must have a mass density ≥80 kg/m³ with an
operating temperature limit of at least 750°C. The following thicknesses must be respected for this material:
Floor 0mm
Installation wall 140mm
Ceiling 100mm
Adjacent wall 80mm
The use of silicate-based insulation allows the insulation thicknesses to be reduced considerably.
A distance of 60mm must be respected between the appliance and the insulation material. If the adjacent
materials are not inflammable or load bearing, this distance can be reduced to 10mm.
The various elements of a cross-section are described below:
A. Inset fire
B. Insulation material
C. Masonry
D. Inflammable wall/elements or load-bearing wall
E. Convection zone
1. 10mm
2. 60mm (regarding inflammable materials)
F. Ceiling made from inflammable materials
G. Furnishing
H. Floor made from non-flammable materials
47


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Saey High Line 80 S at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Saey High Line 80 S in the language / languages: English, Dutch, French as an attachment in your email.

The manual is 2.39 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info