SELECTING THE RPM
The rpm can be adjusted by rotating the knob. The choice of speed depends on the cha-
racteristics of the abrasive paper disc and the material to be worked.
REPLACING THE POLISHING PAD
Pull the used pad off and apply the new pad, pressing it onto the back-up pad.
USABLE DISCS
Polishing pads Ø 150 mm.
MAINTENANCE
All maintenance operations are carried out with the power supply disconnected. At the end
of each work session, or when required, remove any dust from the body of the tool using a
jet of compressed air. Lubricate the machine regularly (every 50 hours of operation) by in-
serting 2/3 drops of specific oil (synthetic oil without silicone, ISO 32) into the compressed
air connection, keeping the device in a vertical position, with the connection
facing upwards. After this operation, connect the machine to the power supply and set it in
motion for a few seconds.Lubricate the machine as described above before storing it for
long periods of inactivity.All damages deriving from incorrect or inadequate lubrication are
excluded from the warranty. No other maintenance operations must be undertaken by
the user. Maintenance and cleaning of the inner parts, like ball bearings, gears etc. or
others, must be carried out only by an authorized Assistance Centre.
NOISE
The noise level produced is 76,8 dB, measured according to regulation EN ISO 3744 +
UNI EN ISO 11203. Warning: wear suitable hearing protections! (see warnings).
MEAN ACCELERATION VALUE
The mean quadratic acceleration value is less than 2,5 m/sec2 measured in accordance
with standard UNI EN 28662 + UNI EN ISO 5349.
GUARANTEE
All tools manufactured by RUPES Spa are guaranteed for 12 months from the date of pur-
chase against fabrication and material defects. All tools must be used only with RUPES
original accessories and spare parts: we refuse all responsibility for damages or accidents
caused by non-observance of this rule which will also cause the termination of the gua-
rantee. The guarantee will no longer be valid if the instructions contained in this booklet
are not followed, if the tool is used for purposes other than that for which it is intended, if it
is dismantled, interfered with in any way or damaged due to neglect. The guarantee will be
made valid by filling-in the form on the inside back cover of this instruction booklet. If the
tool is found to be defective or malfunctions, it should be returned carriage free in one piece
in its original packing together with the guarantee certificate to the manufacturer or to one
of the Assistance Centres listed in the appendix to this booklet. The guarantee does not au-
tomatically imply replacement of the tool. RUPES Spa reserves the right to make any
technical or design modification to its products without prior notice. The manufacturer is
not liable for any print errors. This document voids and replaces previous ones.
TOOL IDENTIFICATION PLATE POSITION AND MEANING OF INFORMATION
1 - Type of tool
2 - Air consumption at full power
3 - Working pressure
4 - Orbital diameter
5 - Tool code number or serial number
6 - Dimensions of the sheets of abrasive paper
7 - Maximum rpm
CONFORMITY DECLARATION
We declared on our responsability that the hand-held non-electric power tool, which is
mentioned in the present operating manual, is in comformity with the Essential Requirements
of Safety of the following Directive:
2006/42/CE Machine
The tests have been carried out in accordance with following Standards:
EN ISO 12100-1: 2003 Safety of machinery. Basic concepts, general principles for design.
Basic terminology, methodology.
EN ISO 12100-2: 2003 Safety of machinery. Basic concepts, general principles for design.
Technical principles.
UNI EN 792-8: 2008 Hand-held non-electric power tools. Safety requirements. Sanders and
polishers.
UNI EN 983: 2009 Safety of machinery. Safety requirements for fluid power systems and their
components.
UNI EN ISO 14121-1: 2007 Safety of machinery. Risk assessment. Principles.
UNI EN ISO 3744:1997Acoustics. Determination of sound power levels of noise sources.
UNI EN ISO 11203: 1997 Acoustics. Noise emitted by machinery and equipment.
UNI EN 28662-1: 1993 Hand-held portable power tools. Measurement of vibrations at the
handle.
UNI EN ISO 5349-1: 2004 Mechanical vibration. Measurement and evaluation of human
exposure to hand-transmitted vibration.
IL PRESIDENTE
G. Valentini
S.p.A
7


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Rupes LHR150N at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Rupes LHR150N in the language / languages: English, German, Dutch, French, Italian, Spanish as an attachment in your email.

The manual is 0,19 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info