9
PARTS OF THE TOOL
1 - Identification plate
2 - ON/OF switch
3 - Speed control
4 - Spindle locking button
5 - Spindle
6 - Side handle
7 - Adjustable protective shield
8 - Dust brush
9 - Collar with protective shield fixing points
10 - Protective shield fixing screws
11 - Disc pad tapered ring nut
12 - Abrasive disc mouting plate
13 - Spanners
14 - Motor ventilation slots
15 - 29 mm Ø suction port
STARTING UP
Before starting-up the tool, ensure that:
- the packaging is complete and does not show signs of having
been damaged during storage or transport;
-the tool is complete; check that the number and type of
components comply with that reported in this instruction
booklet;
-the power supply and socket outlet can support the load
reported in the table and that indicated on the tool identification
plate reproduced and explained on page 11.
ASSEMBLING THE TOOL
- Mount the dust brush (8) securely on the protective shield (push
fit);
- mount the protective shield (7) with collar (10) on the body of
the tool using the screws (9). Ensure that the protrusions on the
collar are inserted in the slots cut into the flange of the shield.
The shield must be mounted around the handle.
After tightening the screws and collar, the shield must be able to
rotate with a slight resistance approximately 20° in order that it
may be positioned as desired by the operator;
- tighten the auxiliary handle (6); it can be mounted on the left or
right of the tool body.
- connect the extraction device by the suction pipe in the nozzle (15).
MOUNTING THE ABRASIVE DISC - BACKING PAD
1. Insert the disc pad (12) on the spindle (5);
2. fit the abrasive disc;
3. screw on the ring nut (11) and tighten it using the pin wrench
(13) preventing the spindle from moving with the17 mm
spanner or with the spindle locking button (4).
BEFORE STARTING THE TOOL
Ensure that:
- the power supply conforms with the characteristics of the tool;
- the power supply cable and plug are in perfect condition;
-the ON/OFF switch works properly though with the power
supply disconnected;
- the spindle locking button (4) is not engaged (rotate the disc
pad by hand for at least one revolution);
- all the parts of the tool have been assembled in the proper
manner and that there are no signs of damage;
- the ventilation slots are not obstructed (14).
STARTING AND STOPPING
- Starting:
push the slide of the switch (2) forward; if the tool is to
be locked in the ON position, apply pressure to the front part of
the slide switch at the same time.
-Stopping:release the slide or, if locked in position, apply
pressure to the back part of the switch and allow it to return to
the stop position.
TEST RUN
Start the tool and check that there are no unusual vibration, no
dismatching movement of the abrasive disc.
Otherwise switch-off the tool immediately and eliminate the
cause.