531521
10
Zoom out
Zoom in
Previous page
1/15
Next page
Filling the water tank.
When the water tank is empty, ame and smoke eect shuts o, and you will hear 2 audible ‘beeps’.
Follow these steps to rell:
1. Press Switch A to (0). (See Fig.2)
2. Pull out the drawer as far as possible by the tab. (See Fig.3)
3. Remove the water tank by lifting upwards and outwards.
4. Place the water tank in sink and remove cap, Anti-clockwise to open. (See Fig.6)
5. Fill tank with ltered tap water with a maximum hardness of 10 dH only. This is necessary to
prolong the life of the ame and smoke producing unit.
In situations with a higher water hardness, the water should be ltered (for example with a Maxtra
lter). Do not use a decalcier.
6. Screw the cap back on, do not overtighten.
7. Return the tank to the sump, with the tank cap facing down and the at side of the tank facing
outward.
8. Press SwitchB once to turn on ame eect. (See manual control section and Fig.2).
9. Press Switch A to ‘ON’ ( I ) position. (See Fig.2)
10. Gently push the drawer back in as far as it will go.
Cleaning.
WARNING – ALWAYS DISCONNECT FROM THE POWER SUPPLY BEFORE CLEANING THE FIRE.
We recommend cleaning the following components once every 2 weeks, particularly in hard water
areas:-
Water Tank, Sump and Seal, Sump lid, Tank cap and seal, Air lter.
For general cleaning use a soft clean duster – never use abrasive cleaners. To remove any accumulation
of dust or u the soft brush attachment of a vacuum cleaner should occasionally be used to clean the
outlet grille of the fan re.
Water tank
1. Remove water tank, as described earlier, put into sink and empty water.
2. Using the supplied brush gently rub the inside surfaces of the cap paying particular attention to the
rubber ring in the outer groove and the centre rubber seal.
3. Put a small quantity of washing up liquid into the tank, ret the cap and shake well, rinse out until all
traces of washing up liquid are gone.
4. Rell with tap water with a maximum hardness of 10 dH only, replace the cap, do not overtighten.
5. Do not use a decalcier when cleaning the appliance, this may shorten the lifetime of the smoke
unit.
Sump
1. Press Switch A to the ‘OFF’ (0) position
2. Gently pull the drawer out as far as possible. (See Fig.3)
3. Remove the water tank by lifting upwards.
4. Disconnect the electrical connector, located on the left side of the sump, by rst loosening the two
retaining screws and gently withdrawing the connector. (See Fig.8)
5. Release the lower sump locking tabs by turning 90º, this allows the sump to be lifted completely
from its location. (See Fig.9)
6. Gently lift up the sump assembly, taking care to keep level so as not to spill any water. Sit the
assembly in the sink. (See Fig.10)
7. Release the two upper sump locking tabs by turning 90º, then lift o the sump lid. (See Fig.11)
8. Carefully tilt, as shown, so that the liquid drains out of the sump. (See Fig.12)
9. Put a small amount of washing up liquid into the sump, and using the supplied brush, gently clean
all surfaces including the metal disc and the rubber seal located in the top grooved surface. Do not
remove the rubber seals. (See Fig.13 and 14)
10. When cleaned, thoroughly rinse the sump with clean water.
11. Clean the outlet surface of the sump lid with the brush and ush out thoroughly with water. (See
Fig.15 & 16)
12. Reverse the above steps to reassemble.
Air lter.
1. Gently pull the drawer out as far as possible. (See Fig.3).
2. Press Switch A to the ‘OFF’ (0) position (See Fig.2)
3. Remove the tank and place in a sink with the cap facing upwards.
4. Gently slide upwards the air lter plastic holder. (See Fig.17)
5. Remove the lter combination from the plastic holder.
6. Gently rinse with water in the sink and dry with fabric towel before returning.
7. Replace the lter combination making sure that the course black lter is in contact with the plastic
holder. (See Fig.18)
8. Replace the tank.
9. Press Switch A to the ‘ON’ ( I ) position (See Fig.2).
10. Close the drawer fully.
Recycling.
For electrical products sold within the European Community. At the end of the electrical products
useful life it should not be disposed of with household waste. Please recycle where facilities exist.
Check with your Local Authority or retailer for recycling advice in your country.
After Sales Service
Should you require after sales service, please get in touch with the supplier through whom you
purchased the appliance.
Symptom Cause Corrective Action
The ame eect will not start. Mains plug is not plugged in.
Switch A is in the ‘ON(I) position, but mode Switch B has not been pressed.
(See Fig.2)
Low water level.
Low voltage connector not connected properly. (See Fig.8)
Check plug is connected to wall socket correctly.
Press Switch B once for ame eect. (See Fig.2)
Check the water tank is full and there is water in the sump.
Check that the connector is inserted correctly. (See Fig.8)
The ame eect is too low. Flame eect control knob is set too low.
(See Fig.2)
The water in the sump may be too high due to the drawer being opened and
closed a number of times, water tank removed a number of times, or the re
has been moved.
Metal Disc at the base of Sump might be dirty (See Fig.13)
Increase level of ame by turning Control knob C to the left slowly. (See Fig.2)
If water level in the sump is more than 40mm, the sump should be removed and
emptied in the sink.
Clean the Metal Disc with the soft brush supplied. (See Fig.13) See ‘Maintenance.
for a step by step procedure.
Unpleasant smell when unit is used. Dirty or stale water.
Using unltered tap water.
Clean the unit as described under maintenance.
Use tap water with a maximum hardness of 10 dH only.
The ame eect has too much smoke. Flame eect setting is too high. Turn the ame eect Control knob C to the right until it is at minimum and
slowly turn to the left, about ¼ a turn, at a time. Give the ame generator some
time to adjust before increasing. (See Fig.2)
Main lamps are not working and there
are no ames or smoke.
There is no water in the tank. Follow instructions under Maintenance, ‘Filling the water tank’.
Check the plug is connected to wall socket correctly.
Switch A’ Fig. 2 is in the ‘ON’ ( I ) position.
Press switch ‘B’ Fig.2 until you can hear one beep only, for ame eect.
Troubleshooting
4
Water is leaking from tank Rubber seal in lid is damaged Refer to dealer for a replacement seal
10


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Ruby Fires RF20 - Mystic Fire at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Ruby Fires RF20 - Mystic Fire in the language / languages: English, German, Dutch, French as an attachment in your email.

The manual is 5,25 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Ruby Fires RF20 - Mystic Fire

Ruby Fires RF20 - Mystic Fire User Manual - Dutch - 7 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info