603202
160
Zoom out
Zoom in
Previous page
1/184
Next page
160
MIDI Implementation
Status
Data byte Status
F0H 41H, dev, 42H, 12H, aaH, bbH, ccH, F7H
ddH, ... eeH, sum
Byte Explanation
F0H Exclusive status
41H ID number (Roland)
dev Device ID (dev: 10H - 1FH, 7FH)
42H Model ID (GS)
12H Command ID (DT1)
aaH Address MSB: upper byte of the starting address of the transmitted
data
bbH Address: middle byte of the starting address of the transmitted
data
ccH Address LSB: lower byte of the starting address of the transmitted
data
ddH Data: the actual data to be transmitted. Multiple bytes of
data are transmitted starting from the address.
: :
eeH Data
sum Checksum
F7H EOX (End Of Exclusive)
* The amount of data that can be transmitted at one time depends on the type of data, and
data will be transmitted from the specified starting address and size. Refer to the address
and size given in “Parameter Address Map” (p. 162).
* Data larger than 256 bytes will be divided into packets of 256 bytes or less, and each
packet will be sent at an interval of about 20 ms.
* Regarding the checksum, please refer to (p. 174)
* Not received when the Receive Exclusive parameter (SYSTEM/MIDI&USB) is OFF.
2. Data Transmission
Channel Voice Messages
When execute the Data Transfer, following Control Changes and Program Change will
transmit.
Control Change
Bank Select (Controller number 0, 32)
Status 2nd byte 3rd byte
BnH 00H mmH
BnH 20H llH
n = MIDI channel number: 0H - FH (ch.1 - 16)
mm, ll = Bank number: 00 00H - 7F 7FH (bank.1 - bank.16384)
Portamento Time (Controller number 5)
Status 2nd byte 3rd byte
BnH 05H vvH
n = MIDI channel number: 0H - FH (ch.1 - 16)
vv = Portamento Time: 00H - 7FH (0 - 127)
Data Entry (Controller number 6, 38)
Status
2nd byte 3rd byte
BnH 06H mmH
BnH 26H llH
n = MIDI channel number: 0H - FH (ch.1 - 16)
mm, ll = the value of the parameter specified by RPN/NRPN
mm = MSB, ll = LSB
Volume (Controller number 7)
Status
2nd byte 3rd byte
BnH 07H vvH
n = MIDI channel number: 0H - FH (ch.1 - 16)
vv = Volume: 00H - 7FH (0 - 127)
Panpot (Controller number 10)
Status 2nd byte 3rd byte
BnH 0AH vvH
n = MIDI channel number: 0H - FH (ch.1 - 16)
vv = Panpot: 00H - 40H - 7FH (Left - Center - Right),
Portamento (Controller number 65)
Status 2nd byte 3rd byte
BnH 41H vvH
n = MIDI channel number: 0H - FH (ch.1 - 16)
vv = Control value: 00H - 7FH (0 - 127) 0 - 63 = OFF, 64 - 127 = ON
Resonance (Controller number 71)
Status 2nd byte 3rd byte
BnH 47H vvH
n = MIDI channel number: 0H - FH (ch.1 - 16)
vv= Resonance value (relative change): 00H - 40H - 7FH (-64 - 0 - +63)
Release Time (Controller number 72)
Status
2nd byte 3rd byte
BnH 48H vvH
n = MIDI channel number: 0H - FH (ch.1 - 16)
vv = Release Time value (relative change): 00H - 40H - 7FH (-64 - 0 - +63)
Attack time (Controller number 73)
Status
2nd byte 3rd byte
BnH 49H vvH
n = MIDI channel number: 0H - FH (ch.1 - 16)
vv = Attack time value (relative change): 00H - 40H - 7FH (-64 - 0 - +63)
Cutoff (Controller number 74)
Status
2nd byte 3rd byte
BnH 4AH vvH
n = MIDI channel number: 0H - FH (ch.1 - 16)
vv = Cutoff value (relative change): 00H - 40H - 7FH (-64 - 0 - +63)
XV-5050_e.book 160 ページ 2003年6月27日 金曜日 午後3時14分
160


Need help? Post your question in this forum.

Forumrules
1

Forum

roland-xv5050

Reset search

  • my xv5050 power is of how can i repair the powerboard Submitted on 14-7-2024 at 03:57

    Reply Report abuse
  • my xv5050 power is of how can i erpaie the powerboad Submitted on 14-7-2024 at 03:53

    Reply Report abuse


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Roland XV5050 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Roland XV5050 in the language / languages: English as an attachment in your email.

The manual is 6,74 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Roland XV5050

Roland XV5050 User Manual - Dutch - 183 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info