603202
159
Zoom out
Zoom in
Previous page
1/184
Next page
159
MIDI Implementation
Appendices
Controller
Status
Data byte Status
F0H 7FH, 7FH, 09H, 03H, 0nH, ccH, ppH, rrH F7H
Byte Explanation
F0H Exclusive status
7FH ID number (universal realtime message)
7FH Device ID (Broadcast)
09H Sub ID#1 (Controller Destination Setting)
03H Sub ID#2 (Control Change)
0nH MIDI Channel (00 - 0F)
ccH Controller number (01 - 1F, 40 - 5F)
ppH Controlled parameter
rrH Controlled range
pp=0 Pitch Control
rr = 28H - 58H -24 - +24 [semitones]
pp=1 Filter Cutoff Control
rr = 00H - 7FH -9600 - +9450 [cents]
pp=2 Amplitude Control
rr = 00H - 7FH 0 - 200%
pp=3 LFO Pitch Depth
rr = 00H - 7FH 0 - 600 [cents]
pp=4 LFO Filter Depth
rr = 00H - 7FH 0 - 2400 [cents]
pp=5 LFO Amplitude Depth
rr = 00H - 7FH 0 - 100%
F7H EOX (End Of Exclusive)
Scale/Octave Tuning Adjust
Status
Data byte Status
F0H 7EH, 7FH, 08H, 08H, ffH, ggH, hhH, ssH... F7
Byte Explanation
F0H Exclusive status
7EH ID number (Universal Non-realtime Message)
7FH Device ID (Broadcast)
08H Sub ID#1 (MIDI Tuning Standard)
08H Sub ID#2 (scale/octave tuning 1-byte form)
ffH Channel/Option byte 1
bits 0 to 1 = channel 15 to 16
bit 2 to 6 = Undefined
ggH Channel byte 2
bits 0 to 6 = channel 8 to 14
hhH Channel byte 3
bits 0 to 6 = channel 1 to 7
ssH 12 byte tuning offset of 12 semitones from C to B
00H = -64 [cents]
40H = 0 [cents] (equal temperament)
7FH = +63 [cents]
F7H EOX (End Of Exclusive)
Key-based Instrument Controllers
Status
Data byte Status
F0H 7FH, 7FH, 0AH, 01H, 0nH, kkH, nnH, vvH F7H
Byte Explanation
F0H Exclusive status
7FH ID number (universal realtime message)
7FH Device ID (Broadcast)
0AH Sub ID#1 (Key-Based Instrument Control)
01H Sub ID#2 (Controller)
0nH MIDI Channel (00 - 0FH)
kkH Key Number
nnH Control Number
vvH Value
nn=07H Level
vv = 00H - 7FH 0 - 200% (Relative)
nn=0AH Pan
vv = 00H - 7FH Left - Right (Absolute)
nn=5BH Reverb Send
vv = 00H - 7FH 0 - 127 (Absolute)
nn=5D Chorus Send
vv = 00H - 7FH 0 - 127 (Absolute)
::
F7 EOX (End Of Exclusive)
* This parameter affects drum instruments only.
Data Transmission
This instrument can use exclusive messages to exchange many varieties of internal settings
with other devices.
The model ID of the exclusive messages used by this instrument is 00H 10H.
Data Request 1 RQ1 (11H)
This message requests the other device to transmit data. The address and size indicate the
type and amount of data that is requested.
When a Data Request message is received, if the device is in a state in which it is able to
transmit data, and if the address and size are appropriate, the requested data is transmitted
as a Data Set 1 (DT1) message. If the conditions are not met, nothing is transmitted.
Status
data byte status
F0H 41H, dev, 00H, 10H, 11H, aaH, bbH, ccH, F7H
ddH, ssH, ttH, uuH, vvH, sum
Byte
Remarks
F0H Exclusive status
41H ID number (Roland)
dev device ID (dev: 10H - 1FH, 7FH)
00H model ID #1 (XV-5050)
10H model ID #2 (XV-5050)
11H command ID (RQ1)
aaH address MSB
bbH address
ccH address
ddH address LSB
ssH size MSB
ttH size
uuH size
vvH size LSB
sum checksum
F7H EOX (End Of Exclusive)
* The size of data that can be transmitted at one time is fixed for each type of data. And
data requests must be made with a fixed starting address and size. Refer to the address
and size given in “Parameter Address Map” (p. 162).
* For the checksum, refer to (p. 174).
* Not received when the Receive Exclusive parameter (SYSTEM/MIDI&USB) is OFF.
Data set 1 DT1 (12H)
Status
Data byte Status
F0H 41H, dev, 00H, 10H, 12H, aaH, bbH, F7H
ccH, ddH, eeH, ... ffH, sum
Byte Explanation
F0H Exclusive status
41H ID number (Roland)
dev Device ID (dev: 00H - 1FH, 7FH)
00H Model ID #1 (XV-5050)
10H Model ID #2 (XV-5050)
12H Command ID (DT1)
aaH Address MSB: upper byte of the starting address of the data to be
sent
bbH Address: upper middle byte of the starting address of the data
to be sent
ccH Address: lower middle byte of the starting address of the data
to be sent
ddH Address LSB: lower byte of the starting address of the data to be
sent.
eeH Data: the actual data to be sent. Multiple bytes of data are
transmitted in order starting from the address.
: :
ffH Data
sum Checksum
F7H EOX (End Of Exclusive)
* The amount of data that can be transmitted at one time depends on the type of data, and
data will be transmitted from the specified starting address and size. Refer to the address
and size given in “Parameter Address Map” (p. 162).
* Data larger than 256 bytes will be divided into packets of 256 bytes or less, and each
packet will be sent at an interval of about 20 ms.
* Regarding the checksum, please refer to (p. 174)
* Not received when the Receive Exclusive parameter (SYSTEM/MIDI&USB) is OFF.
XV-5050_e.book 159 ページ 2003年6月27日 金曜日 午後3時14分
159


Need help? Post your question in this forum.

Forumrules
1

Forum

roland-xv5050

Reset search

  • my xv5050 power is of how can i repair the powerboard Submitted on 14-7-2024 at 03:57

    Reply Report abuse
  • my xv5050 power is of how can i erpaie the powerboad Submitted on 14-7-2024 at 03:53

    Reply Report abuse


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Roland XV5050 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Roland XV5050 in the language / languages: English as an attachment in your email.

The manual is 6,74 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Roland XV5050

Roland XV5050 User Manual - Dutch - 183 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info