MIDI Implementatie
* The time code types defined by the MIDI specification correspond to the BR-1600CD
Sync parameter “MTC Type” as follows.
MIDI specification setting “MTC Type” setting
0 = 24 Frames / Sec 24
1 = 25 Frames / Sec 25
2 = 30 Frames / Sec (Drop Frame) 29D
3 = 30 Frames / Sec (Non Drop Frame 29N or 30
zzzzz Hours
Song Position Pointer
Status 2nd byte 3rd byte
F2H mmH nnH
mm, nn=Song position point: 00H 00H - 7FH 7FH
* The current position is transmitted by the Song Position Pointer Message when the BR-
1600CD is stopped, or the locate operation has been performed, if the SYNC parameter
“Sync Generator” is set to “MIDI CLOCK.”
System Realtime Messages
Timing Clock
Status
F8H
* Transmitted when “Sync Generator” is “MIDI CLOCK” in the SYNC parameter.
Start
Status
FAH
* Transmitted when “Sync Generator” is “MIDI CLOCK” in the SYNC parameter.
Continue
Status
FBH
* Transmitted when “Sync Generator” is “MIDI CLOCK” in the SYNC parameter.
Stop
Status
FCH
* Transmitted when “Sync Generator” is “MIDI CLOCK” in the SYNC parameter.
Active Sensing
Status
FEH
* This is transmitted at intervals of approximately 200 msec.
System Exclusive Messages
Universal System Exclusive Message
Identity Reply Message
* Receiving Identity Request Message, the Fantom send this message.
Status Data byte Status
F0H 7EH, dev, 06H, 02H, 41H, 71H, 01H F7H
00H, 00H, 00H, 00H, 00H, 00H
Byte
Remarks
F0H Exclusive status
7EH ID number (Universal Non-realtime Message)
dev Device ID (dev: 10H - 1FH)
06H Sub ID#1 (General Information)
02H Sub ID#2 (Identity Reply)
41H ID number (Roland)
71H 01H Device family code
00H 00H Device family number code
00H 00H 00H 00H Software revision level
F7H EOX (End of Exclusive)
For instructions on setting the device ID, refer to “How to set the device ID:” (p. 289).
MIDI Machine Control Command
Status Data byte Status
F0H 7FH, Dev, 06H, aaH, ..., bbH F7H
Byte Remars
F0H Exlusive Status
7FH Universal System Exclusive Realtime Header
Dev Device ID (7FH)
06H MMC command message
aaH command
: :
bbH command
F7H EOX (End of Exclusive)
STOP (MCS)
Status Data byte Status
F0H 7FH, Dev, 06H, 01H F7H
Byte Remarks
F0H Exclusive status
7FH Universal System Exclusive Realtime Header
Dev Device ID (7FH)
06H MMC command message
01H STOP (MCS)
F7H EOX (End of Exclusive)
* If the transport switch [STOP] was pressed, the BR-1600CD transmits this message.
DEFERRED PLAY (MCS)
Status Data byte Status
F0H 7FH, Dev, 06H, 03H F7H
Byte Remarks
F0H Exclusive status
7FH Universal System Exclusive Realtime Header
Dev Device ID (7FH)
06H MMC command message
03H DEFERRED PLAY (MCS)
F7H EOX (End of Exclusive)
* If the transport switch [PLAY] was pressed, the BR-1600CD transmits this message.
RECORD STROBE
Status Data byte Status
F0H 7FH, Dev, 06H, 06H F7H
Byte Remarks
F0H Exclusive status
7FH Universal System Exclusive Realtime Header
Dev Device ID (7FH)
06H MMC command message
06H RECORD STROBE
F7H EOX (End of Exclusive)
* Transmitted when recording to the audio tracks begins.
RECORD EXIT
Status Data byte Status
F0H 7FH, Dev, 06H, 07H F7H
Byte Remarks
F0H Exclusive status
7FH Universal System Exclusive Realtime Header
Dev Device ID (7FH)
06H MMC command message
07H RECORD EXIT
F7H EOX (End of Exclusive)
* Transmitted when recording to the audio tracks ends.
MMC RESET
Status Data byte Status
F0H 7FH, Dev, 06H, 0DH F7H
Byte Remarks
F0H Exclusive status
7FH Universal System Exclusive Realtime Header
Dev Device ID (7FH)
06H MMC command message
0DH MMC RESET
F7H EOX (End of Exclusive)
*When powered on the BR-1600CD transmits this message.
368


Need help? Post your question in this forum.

Forumrules
1

Forum

roland-br-1600-cd

Reset search

  • het lukt me niet om 2 sporen over te zetten (of ineens op te nemen) naar 11/12 13/14 of 15/16
    ik vind er ook niets over terug in de handleiding of op internet. Submitted on 28-7-2023 at 14:01

    Reply Report abuse


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Roland BR-1600 CD at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Roland BR-1600 CD in the language / languages: Dutch as an attachment in your email.

The manual is 20,87 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info