Supplementary Notes
If the system software of the VM-C7200/C7100
is version 1.10 or later;
If the system software of the VM-C7200/C7100 is version 1.10 or later, following functions are supported.
Clock source setting
You can set up the ADA-7000’s clock source with the
VM-C7200/C7100 console.
1. Hold down [SHIFT], and press [PROJECT]. SYSTEM menu appears in the display.
2. Select “SYSTEM CONFIG” and go to “R-BUS 1(/2/3)” page.
3. Following page appears in the display.
fig.ada_70
* If the above menu does not appear in the “R-BUS 1(/2/3)” page of “SYSTEM CONFIG” menu, please turn off the
power of whole system, check the R-BUS connection and turn on again.
4. Select a desired source with [V1 (CLOCK SOURCE)] knob.
5. Press [F1 (SET)] and the clock source you selected is activated.
6. If you select “INTERNAL” for the clock source, set the sampling rate with [V3 (SAMPLING RATE)] knob.
7. Press [F3 (SET)] and the sampling rate you selected is activated.
FRONT PANEL CONTROL
In the R-BUS 1(/2/3) page, you can prohibit the ADA-7000’s panel operation.
1. Hold down [SHIFT], and press [PROJECT]. SYSTEM menu appears in the display.
2. Select “SYSTEM CONFIG” and go to “R-BUS 1(/2/3)” page.
3. Press [F5 (FRONT PANEL CONTROL)].
Highlight ON: Panel control enabled
Normal ON: Panel control invalid
Remote control of the gain and phantom power
You can control the gain setting and phantom power on/off with the VM-C7200/C7100 console.
1. Press [MULTI IN 1-24] in the “SECTION” block.
2. Press [PREAMP GAIN] in the “PARAM VIEW on Fader” block.
3. Control the gain and phantom power on/off in the same manner as for the [INPUT].
* PAD on the ADA-7000 is automatically switched on/off according to the gain setting.
17


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Roland ADA-7000 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Roland ADA-7000 in the language / languages: English as an attachment in your email.

The manual is 0,45 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info