Initial Setup
Output Connections
1. Use RCA cables to connect the output jacks of the 3Sixty.3 to the input jacks on the amplifier(s) you have selected for your system. The 3Sixty.3 will
allow you to connect up to 8 channels of output. Follow the instructions in your amplifier manual for connecting the rest of your system.
NOTE: DO NOT chassis ground any of the leads as unstable operation may result & ensure to follow the diagram for proper signal polarity.
2. Based on the input circuit of your amplifier, select either a balanced or unbalanced output for the 3Sixty.3 to match your amplifiers input. The 3Sixty.3
utilizes a special compensation network to ensure in either position the maximum output voltage is 8VRMS. For most RF amplifiers you are going to want
the switch positioned in the unbalanced position.
PC Software Installation
1. Insert the supplied 3Sixty.3 setup disk and follow the on screen prompts to load the software. If a prompt does not appear you will have to select the CD
ROM drive on you PC to open the 3Sixty.3 setup disk, and select the file “RF3SixtyUI.msi” and follow the on screen prompts.
NOTE: A PC is required for initial setup and adjustments for the 3Sixty.3 unit to properly work with your system. The PC must use a Windows XP, VISTA,
or 7 OS with at least one USB connection and have an internet connection.
2. The 3Sixty.3 user interface (UI) will place the RF icon on your desktop. Double click the RF icon to open the UI. In the lower right corner you will see a
prompt to update the UI if an update is available (must have a working Internet connection). If the UI is up to date you will have a green check mark in the
lower right corner and it will say “You already have the latest version” if you move your curser over it. If an update is available double clicking on it then
follow the on screen prompts to update your UI. Close the UI.
NOTE: You can also manually check for updates by moving the curser over the RF logo in the upper left hand corner and select “Check for updates” This
will ensure you have the latest UI version and 3Sixty.3 processor firmware version.
3. To check which version of UI and processor firmware you are using moving the curser over the RF logo in the upper left hand corner and select “About”.
NOTE: In order to check the version number of the 3Sixty.3 processors firmware the 3Sixty.3 processor must be connected to the PC through the USB
cable.
Connecting to a PC & Updating
NOTE: Before starting the system ensure that the volume is all the way down on the source unit, the factory or any external EQ’s are set to flat, the
amplifier(s) EQ is set to flat and the amplifier(s) gain(s) are set to minimum.
1. Connect the unit to a PC; turn the unit on by turning the key to the accessory position (3Sixty.3 LED should be white), using the supplied USB cable,
connect the 3Sixty.3 processor to the PC (3Sixty.3 LED should turn solid blue). Open the UI. To disconnect the unit, close the UI, Disconnect the USB cable
(3Sixty.3 LED should turn white), and turn off the 3Sixty.3.
NOTE: The unit must be powered on (LED should be white) before connecting to a PC or the unit will enter DEMO mode. DEMO mode allows you only
limited function of the user interface. In DEMO mode you can update your processor but you cannot read or write EQ functions.
NOTE: The remote level control is disabled and will have no LED on while connected to the PC. The remote simulator at the top of the user interface (UI)
screen is used to preform the wired remote controllers functions while connected to a PC.
2. Update the unit; Open up the UI by double clicking the RF icon on your desk top. In the lower left corner of the UI there should be a green circle and it
should display “device connected”. The LED should switch from white to blue (flashes blue when communicating). If the 3Sixty.3 processor is up to date
you will have a green check mark in the lower right corner and it will say “You already have the latest version” if you move your curser over it. If an update
is available double clicking on it then follow the on screen prompts to update your 3Sixty.3 processor.
NOTE: If the device is plugged in and the UI is still displaying “No device connected’ check that the unit is powered on, and the cable connections are
good.
NOTE: You can also manually update the 3Sixty.3 processor firmware updates by selecting the “DEVICE” tab in the upper left hand corner, then selecting
“Upgrade Firmware” from the drop down menu. Follow the on screen prompts to update your 3Sixty.3 processor.
9


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Rockford Fosgate 3 SIXTY.3 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Rockford Fosgate 3 SIXTY.3 in the language / languages: English as an attachment in your email.

The manual is 6,77 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Rockford Fosgate 3 SIXTY.3

Rockford Fosgate 3 SIXTY.3 User Manual - German - 28 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info