Part 1 - INSTALLATION INSTRUCTIONS
1 - GENERAL INFORMATION
This cooker hood is designed to be installed in the lower part of a cabinet placed
above a hotplate fitted against a wall. It can be used either in the extraction (ducted
to the outside) or in the recirculation mode (internal recycling). Before starting the
installation, consideration should be given to the difficulties to be found during
installation. The installation work must be undertaken by a qualified and
competent person in conformity to the rules concerning the evacuation of
contaminated air. The manufacturer disclaims all liability for any damage or
injury caused as a result of not following the instructions for installation
contained in the following text.
2 - SAFETY WARNINGS
2.1 - When used in the extraction mode, the cooker hood ducting must not be connected to
a flue which is used for exhausting fumes from appliances supplied with energy other
than electric, such as a central heating flue or water heating flue.
2.2 - Before connecting to the mains supply ensure that the mains voltage corresponds with
the voltage on the rating plate inside the hood.
2.3 - Connect the cooker hood to the mains via a bipolar switch which has 3 mm clearance
between the contacts.
2.4 - The appliance must be earthed.
2.5 - When installed, the hood must be positioned at least 65 cm above the hotplate.
2.6 - Never do flambé cooking under this cooker hood.
2.7 - Never leave frying pans unattended during use as overheated fat and oil may catch fire.
2.8 - Before carrying out any kind of maintenance or cleaning, disconnect the hood from the
mains supply.
2.9 - If the room where the cooker hood is to be used contains a fuel burning appliance such
as a central heating boiler then this must be of the room sealed or balanced flue type.
If other types of flue or appliance are fitted, ensure that there is an adequate supply of
air into the room. When the cooker hood is used in conjunction with appliances supplied
with energy other than electric, the negative pressure in the room must not exceed 0,04
mbar to prevent fumes being drawn back into the room by the cooker hood.
3 - INSTALLATION
This unit belongs to the category of semi-fitted hoods. The top portion is inserted
inside the overhead unit. After assembly, the pull-out undercarriage is positioned
outside the overhead unit and must be pulled out into a working position.
3.1 - Installation in the overhead unit
Using the template provided, cut the opening required to insert the top portion of the
hood in the base of the overhead unit. Open the pull-out undercarriage and remove
8


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Roblin SL 955 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Roblin SL 955 in the language / languages: English, German, Dutch, French, Italian, Spanish as an attachment in your email.

The manual is 0,6 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info