747912
16
Zoom out
Zoom in
Previous page
1/38
Next page
16
Model name function
Assign a name to the model memory. By giving each model a name that is immediately recognizable, you can quickly select
the correct model, and minimize the chance of flying wrong model memory that could lead to a crash.
To assign a name
1. Access the Model Select function in the programming mode (by pressing the MODE and
SELECT keys simultaneously and holding them down for one second). To select the model
number you wish to change, press the DATA INPUT lever and hold it down for 0.5 seconds
until the desired model number appears..
2. Push SELECT key four times after seeing on the screen the model memory where you want
to set the model name. Then you will see the model name on the screen.
3. Choose a character for the first digit by using DATA INPUT lever. Then move to the next digit
by pressing the SELECT key and choose a character in the same way. Continue choosing
characters for the third and fourth digits. You can use up to four characters for the name.
REVR Servo Reversing
The servo reversing function is used to change the direction that a servo responds to a control input from the transmitter
(stick or switch). After using the reversing function, check
all the controls on the model to be certain they are operating in the
correct direction and that you did not inadvertently reverse a servo other than the one intended. Reversing the wrong servo (and
not checking the response of the controls before each flight) may be the most common cause of a crash!
To reverse a servo:
1. Enter the programming mode and use the MODE key to access the REVR function.
2. Use the SELECT key to select the channel you wish to reverse.
3. Push the DATA INPUT lever downward for 0.5 seconds to reverse the servo (REV), or push
the lever upward for 0.5 seconds to make the servo operate normally (NOR). The arrow will
indicate the condition of the servo (normal or reversed).
4. Use the SELECT key to display other channels to be reversed.
Dual Rates / Exponential Settings
The aileron, elevator and rudder dual rates on the 6EXHP are simultaneously activated by the dual rate switch. The amount of
travel decrease for each control may be set between 0% and 100% of the values set for the end points (explained in End Point
Adjustment on page 17).
Note: It is possible to set a dual rate value to zero, thus causing no response from that channel. If the dual rates are
inadvertently set to zero, a crash could result.
Note: When performing initial model setup, the E.P.A.s should be set prior to setting the dual rates. When setting the E.P.A.s
for the first time on a new model, the dual rates should be set to 100%.
D/R Dual Rate Settings
To set the dual rates:
1. Enter the programming mode. Access the D/R screen with the MODE key.
2. Select the channel to be adjusted (1-aileron, 2-elevator, 4-rudder) by pressing the SELECT
key until the desired channel number appears on the left side on the screen. Note: If an
EXPO appears on the screen, you have pressed the SELECT key too many times and
displayed the values for the exponentials (explained later). Press the SELECT key to return
to the dual rate values.
3. Place the dual rate switch in the desired position for the value you wish to change. (Generally,
pilots prefer to have the switch in the “up” position for the high rate, and in the “down”
position for the low rate.)
4. Change the dual rate value using the DATA INPUT lever until the desired control throw is achieved. If you wish to change
the control throw when the switch is in the other position as well, flip the switch, then use the DATA INPUT lever to change
16


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Robbe Futaba T6EX at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Robbe Futaba T6EX in the language / languages: English as an attachment in your email.

The manual is 2,28 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info