744652
11
Zoom out
Zoom in
Previous page
1/24
Next page
|11
EN
10
4. TECHNOLOGY AND SAFETY FUNCTIONS
The technological advances in your new combi stove are the result of years of
testing and practical experience. The practical advantages of your pellet stove
are convincing:
Operating comfort
The microprocessor-controlled combustion regulation optimises the interaction
of flue gas blower and screw using the current combustion chamber
temperature. This guarantees optimum combustion and operating status.
All function can be regulated centrally using the integrated operating unit. The
intuitive graphic interface permits easy operation; all the settings can be made
quickly and simply.
Top efficiency - lowest emissions
A very great heat exchange surface together with optimum combustion air
control leads to excellent fuel utilisation.
Fine continuous pellet dosing in an optimised burner pot made of high-quality
grey cast iron leads to virtually complete combustion with very good exhaust
gas values - and this is guaranteed in every operating phase.
Note
During operation, the flame noise, pellets dropping and actuation of the
electronic components are audible due to the automatic control.
Pressure monitoring
The negative pressure in the combustion chamber is continuously monitored
during operation. Below a defined threshold, a correct operation can not be
guaranteed and the unit will switch off with the fault message „NOT ENOUGH
LOW PRESSURE“ for safety reason.
Note
After the occurrence of the error message, maintenance or cleaning work
necessarily has to be carried out! If the error occurs again, a safe operation is
no longer guaranteed, the service must be informed immediately.
Note
If the stove is used in a habitation together with a kitchen hood or a ventilation
(WC) it might happen that the built-in pressure switch stops the stove. If using
the hood make sure that an adequate supply of air is ensured.
Low-temperature shutdown
The unit switches off if the stove cools below a minimum temperature. This
switch-off may occur if pellet ignition is delayed.
Electrical excess current protection
The stove has a main fuse (at the rear) to protect against excess current.
Automatic cleaning cycle
The speed of the flue gas fan is increased every hour for a short period to blow
ash from the burn pot, increasing the operational safety. The status indicator
CLEAN appears on the display.
Only for stoves with turning grids:
Every 6 hours (interval adjustable) an additionally automatic big cleaning cycle
is performed. The stove stops, the automatic cleaning tilts the grid and then
re-ignites the stove. The status indicator BIG CLEAN appears on the display
continuously. The cleaning procedure with tilting the grid is to convey ash and
clinker from the burn pot into the ash drawer.
Note
This additional function does not replace a manual cleaning as described in
CLEANING and MAINTENANCE, as this is absolutely necessary to do regularly.
Note
Due to the turning grid there is a certain generation of noise during the
automatic cleaning cycle (START or BIG CLEAN).
Component monitoring
All the electrical components used are continuously monitored during operation.
If a component is defective or can no longer be actuated correctly, then
operation is stopped and a warning or error message is issued (see MANUAL
TOUCH DISPLAY).
Auger motor monitoring
Too long or wet pellets as well as pellets with too high dust content (see BRIEF
INFORMATION ON FUEL PELLETS) can cause so-called “auger jammers” in the
auger channel. This may also happen if the pellets accumulate in the burn pot
and the backlog reaches into the chute. The auger motor reacts in both cases
with an increased current consumption, which causes the error message:
DISCHARGE MOTOR BLOCKED. The stove will be stopped. Please call the
customer service immediately.
Power failure (during heating)
After a brief power failure, the operating functions that were set before the
power failure, continues. If the power failure lasts longer, the stove goes to start
phase if sufficient temperature or embers are present. If the power failure lasts
too long, the stove goes into the stop phase. The flue gas fan continues to burn
any pellet residues (approximately 10 minutes). Then it will restart automatically.
Power failure (during the initial stage)
After a brief power failure the boot process continues. If the power failure lasts
longer, the stove is in the stop phase. The flue gas fan continues to burn any
pellet residues (approximately 10 minutes). Then it will restart automatically.
11


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Rika Sumo at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Rika Sumo in the language / languages: English as an attachment in your email.

The manual is 15,54 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Rika Sumo

Rika Sumo User Manual - German - 24 pages

Rika Sumo User Manual - Dutch - 24 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info