744652
9
Zoom out
Zoom in
Previous page
1/24
Next page
|9
EN
8
Prior to set up
Floor bearing capacity
Ensure that the substructure is capable of bearing the weight of the stove prior
to set-up.
Note
No modifications may be made to the firing installation. This also leads to loss
of warranty and guarantee.
Floor protection
A glass, sheet steel or ceramic plate is recommended, if the floor is combustible
(wood, carpet, etc.). Please observe the respective local regulations and rules.
Flue pipe connection
QFlue pipes pose a particular source of hazard regarding gas leaks and
fire. Get the advice of an authorised specialist company for the layout and
assembly.
QPlease observe the corresponding installation guidelines for walls panelled
with wood when connecting your flue pipes to the stove.
QObserve the formation of flue gas (atmospheric inversion) and draughts
when the weather is unfavourable.
QInfeed of too little combustion air can lead to smoke in the rooms or to flue
gas leaks. Hazardous deposits in the stove and chimney may also occur.
QIf flue gas escapes, let the fire burn out and check whether all the air inlet
openings are free and the flue gas pipes and the stove pipe are clean. If in
doubt notify the master chimney sweep since draught malfunctions may be
connected to your chimney.
The correct chimney connection
There are several ways to connect your stove to the chimney, eg:
*1
*2
*3
*1
*2
*3
1) wind break, 2) chimney, 3) inspection opening
For the selection of the connection and to ensure a proper connection between
the stove and chimney, please read the guide „INSTALLING THE STOVE“ or ask
your local chimney sweep.
Stoves type 1 (BA 1):
QSuitable for multiple occupancy. (Note the different country regulations.)
QThese may only be operated with the combustion chamber door closed.
QThe combustion chamber door is to be kept closed when the stove is not
in operation.
QFouling of the chimney i.e. deposits of highly inflammable materials such as
soot and tar and subsequently fire in the chimney may occur if the chimney
is miscalculated and dimensioned wrong.
QIf this occurs, disconnect the mains plug. Phone the fire brigade and get
yourself and other residents out of harm’s way.
Note
Your pellet stove has been tested as a room-air independent stove according
to EN14785. It can be operated room air dependent or room air independent.
ROOM-AIR INDEPENDENT OPERATION:
The stove is certificated for type FC52x / FC62x of the approval principles for
the inspection and evaluation of ambient air independent fireplaces specified
by the Deutsches Institut für Bautechnik (DIBT) (German Institute for Building
Technology). Thanks to an air-tight configuration of the air supply line and flue
pipes the stove may be operated in air-tight rooms and in rooms with room-air
installations (e.g. controlled ventilation and venting systems, extractors etc.).
ROOM-AIR DEPENDENT OPERATION:
In combination with room-air installations (e.g. controlled ventilation and
venting systems (extractors etc.) it must be ensured that the stove and
the room air system are monitored and safeguarded mutually (e.g. via
a differential pressure controller). The combustion air infeed of approx.
20 m3/h must be ensured.
Please observe the respective local regulations and rules in consultation with
your master chimney sweep. For changes after the printing of this manual, we
can not assume any liability. We reserve the right to change without notice.
Note
For the indispensable cleaning concerning Sumo RAO and Filo RAO the
application of the interceptor for ashes is strongly recommended.
9


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Rika Sumo at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Rika Sumo in the language / languages: English as an attachment in your email.

The manual is 15,54 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Rika Sumo

Rika Sumo User Manual - German - 24 pages

Rika Sumo User Manual - Dutch - 24 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info