744651
15
Zoom out
Zoom in
Previous page
1/28
Next page
|15
14
EN
4. TECHNOLOGY AND SAFETY FUNCTIONS
The technological advances in your new combi stove are the result of
years of testing and practical experience. The practical advantages
of your pellet stove are convincing:
Operating comfort
All functions can be regulated using the integrated touch display.
The user-friendly interface permits extremely easy operation.
Top efficiency - lowest emissions
All processes in the stove are fully automated. The parameters
QAir control
QTemperature monitoring
QPellet dosing
are continuously optimised. This guarantees optimum combustion.
The result are low consumption and very good exhaust gas values
that even undercut the legally permitted limits.
Note
Due to the automated control, you may hear flame fluttering,
falling pellets and sounds from the activation of the electronic
components during operation.
DAR - Dynamic Air Regulation
A differential pressure sensor in the supply air system measures the
air flow. The fan speed is adjusted automatically and guarantees
optimum combustion.
The air pipe of an external supply air pipe can also be monitored in
this way.
Pressure monitoring
The negative pressure in the combustion chamber is continuously
monitored during operation. Below a defined threshold, a correct
operation can not be guaranteed and the unit will switch off with the
fault message „NOT ENOUGH LOW PRESSURE“ for safety reason.
Note
If the stove is used in a habitation together with a kitchen hood or
a ventilation (WC) it might happen that the built-in pressure switch
stops the stove. If using the hood make sure that an adequate
supply of air is ensured.
Low-temperature shutdown
The unit switches off if the stove cools below a minimum temperature.
This switch-off may occur if pellet ignition is delayed.
Electrical excess current protection
The stove has a main fuse (at the rear) to protect against excess
current.
Automatic cleaning cycle
The speed of the flue gas fan is increased every hour for a short
period to blow ash from the burn pot, increasing the operational
safety. The status indicator CLEAN appears on the display.
Only for stoves with turning grids:
Every 6 hours (interval adjustable) an additionally automatic big
cleaning cycle is performed. The stove stops, the automatic cleaning
tilts the grid and then re-ignites the stove. The status indicator BIG
CLEAN appears on the display continuously. The cleaning procedure
with tilting the grid is to convey ash and clinker from the burn pot
into the ash drawer.
Note
This additional function does not replace a manual cleaning as
described in CLEANING and MAINTENANCE, as this is absolutely
necessary to do regularly.
Note
Due to the turning grid there is a certain generation of noise during
the automatic cleaning cycle (START or BIG CLEAN.
Component monitoring
All the electrical components used are continuously monitored
during operation. If a component is defective or can no longer be
actuated correctly, then operation is stopped and a warning or error
message is issued (see MANUAL TOUCH DISPLAY).
Auger motor monitoring
Too long or wet pellets as well as pellets with too high dust content
(see BRIEF INFORMATION ON FUEL PELLETS) can cause so-called
auger jammers” in the auger channel. This may also happen if the
pellets accumulate in the burn pot and the backlog reaches into
the chute. The auger motor reacts in both cases with an increased
current consumption, which causes the error message: DISCHARGE
MOTOR BLOCKED. The stove will be stopped. Please call the
customer service immediately.
Power failure (during heating)
After a brief power failure, the operating functions that were set
before the power failure, continues. If the power failure lasts longer,
the stove goes to start phase if sufficient temperature or embers are
present. If the power failure lasts too long, the stove goes into the
stop phase. The flue gas fan continues to burn any pellet residues
(approximately 10 minutes). Then it will restart automatically.
Power failure (during the initial stage)
After a brief power failure the boot process continues. If the power
failure lasts longer, the stove is in the stop phase. The flue gas fan
continues to burn any pellet residues (approximately 10 minutes).
Then it will restart automatically.
15


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Rika Sono RAO at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Rika Sono RAO in the language / languages: English as an attachment in your email.

The manual is 13,73 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Rika Sono RAO

Rika Sono RAO Installation Guide - English - 48 pages

Rika Sono RAO User Manual - German - 28 pages

Rika Sono RAO Installation Guide - German, Dutch - 48 pages

Rika Sono RAO User Manual - Dutch - 28 pages

Rika Sono RAO Installation Guide - French, Italian - 48 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info